Response from MY PLUMBER HEATING COOLING & ELECTRICAL:
Here at My Plumber Heating, Cooling and Electrical, customer feedback like this is simply priceless, thank you for the continued loyalty and support!
Response from MY PLUMBER HEATING COOLING & ELECTRICAL:
Here at My Plumber Heating and Cooling, customer feedback like this is simply priceless, thank you for the continued loyalty and support!
1. Removed and replaced kitchen sink faucet with pull out sprayer replacing a white faucet with a polished chrome 2. Removed and replaced hot and cold emergency shut off valve under kitchen sink leading to kitchen faucet, 3. Repaired water closet located in upstairs master bathroom by minor tank rebuild replacing water closet fill valve, water closet coastal blue flapper, and water closet supply line...
REPAIRED 3/4’’ COPPER PIPE REPAIRED BY THE WASHING MACHINE ROOM. TESTED EVERYTHING NO LEAKS. 90 DAYS WARRANTY ON REPAIRED. SENIOR DISCOUNT. %10.
repair shower faucet posi temp replace cartridge and handle
INSTALLED NEW 3/4 ‘’ PRV, TESTED NO LEAKS.. SPOT A LEAK COMING FROM ABOVE THE WATER HEATER 3’4’’ COPPER PIPE, AND GATE VALVE CORRODED EMERGENCY CUT OFF VALVE COLD SIDE OF THE WATER HEATER. GIVE OPTIONS TO REPAIRED TODAY.,. SHE WOULD LIKE TO DISCUSS IT WHEN HER HUSBAND RETURN..
replace angle valve cold side for lav in powder bath
snake floor drain 21’ past stack and cleared stoppage at about 15’. Pulled back metal drain cover and what looks like hair. Pictures attached. Test and all seems well at this time.
Psi 60 replace prv also major rebuild in powder bath and hb
Stoppage Format 1) What type of stoppage? A: 2) Where did you snake from? If yes- does it go into ceiling or basement floor? A: 3) How far did you snake? A: 4) Where did you encounter the blockage? A: 5) Did you pull anything back if so what? A: 6) What type of pipe? A: 7) On septic / sewer if septic when was it last pumped? A: 8) Where’s county/city main at? A: 9) Was the problem on or off the property? A: 10) Is a Camera Inspection Needed? If so Reason. Make sure the Homeowner/Building Owner will be present at the time of service A: Psi 60 chl - Snake floor drain in the laundry room about 6 cables and got the line clear everything draining fine no issues sold bioclean
Psi 65 repalce pressure relief valve on 16 years old water heater recommended to replace tank est 2989.00
I inspected furnace system to include: R-410 TXV -All electrical wiring, motors, and components -All safeties ok -drain is clear -evap coils are clean -condenser coils are clean Iddb 72 Oddb 40 Blower assembly is dirty and needs to be pulled and cleaned. Honeywell EAC cells are dirty. Vacuumed was not sufficient to clean and should be replaced. Ducts are dirty and need to be cleaned. Uv bulb is failed and needs to be replaced.
Performed hsp inspection found most of plumbing in good shape just older. Replace anode rod ,replace tmp valve flushed and drained water heater everything it working great at this time. Thank you for your business