MY PLUMBER HEATING COOLING & ELECTRICAL
MANASSAS, VA 20109
800-280-2820

Local Reviews
for midland, va

Rated 5.0 out of 5 stars based on 2 customer reviews

Great Job

It was a pleasure to do business with your company. Sybil needed some good workers in her house for a change. Thank Sissy.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Above and beyond normal work.

The best work and people that i have ever dealt with from start to finish.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for midland, va

Curtis L.

Curtis L. Job Checkin

Replaced sewage ejector pump. 2 year parts and labor warranty


RANDALL P.

RANDALL P. Job Checkin

Replaced switch with 40/60 and tested operation. Working properly at this time.


MIGUEL G.

MIGUEL G. Job Checkin

Upon arrival installed a power surge protector onto HVAC package unit. Cycled operations, unit is on line at this time.


LEE D.

LEE D. Job Checkin

Cut out and replaced approx 12 ft of low volt cable.


JESSE W.

JESSE W. Job Checkin

Replaced faulty components once correct components arrived,installed components,started system,compressor,failed on start up,need to replace compressors,1st stage operational at this time.


BARRY B.

BARRY B. Job Checkin

Came out today and performed system tune up on a Goodman heat pump system,check blower motor,wheel,and assembly(okay),check electrical absorption system 10mfd(reading 9.8mfd),check air filter(clean),check evaporator coil(clean),flush drain pan,ez trap,and condensate drain line,check condensate pump(pumping good),uv light has 745 left before bolt replacement,check outdoor heat pump,check electrical delivery system,check electrical absorption system 40/5mfd(reading 40/5.02 mfd),check fan motor(good)check compressor(installed start electrical absorption system SPP8),check condenser coil(clean),check defrost control board,check refrigerant pressure 65/190 R-22,suction line temperature48F,suction saturation temperature 38F,superheat 10F,liquid line temperature 84F,saturation liquid temperature 97F,sub cooling 13F,check all electrical connections and tighten all loose connections, check all cooling, system is cooling and operational


BARRY B.

BARRY B. Job Checkin

Came out today and performed system tune up on a Goodman heat pump system,check blower motor,wheel,and assembly(okay),check electrical absorption system 10mfd(reading 9.8mfd),check air filter(clean),check evaporator coil(clean),flush drain pan,ez trap,and condensate drain line,check condensate pump(pumping good),uv light has 745 left before bolt replacement,check outdoor heat pump,check electrical delivery system,check electrical absorption system 40/5mfd(reading 40/5.02 mfd),check fan motor(good)check compressor(installed start electrical absorption system SPP8),check condenser coil(clean),check defrost control board,check refrigerant pressure 65/190 R-22,suction line temperature48F,suction saturation temperature 38F,superheat 10F,liquid line temperature 84F,saturation liquid temperature 97F,sub cooling 13F,check all electrical connections and tighten all loose connections, check all cooling, system is cooling and operational


BARRY B.

BARRY B. Job Checkin

Came out today and performed system tune up on a Goodman heat pump system,check blower motor,wheel,and assembly(okay),check electrical absorption system 10mfd(reading 9.8mfd),check air filter(clean),check evaporator coil(clean),flush drain pan,ez trap,and condensate drain line,check condensate pump(pumping good),uv light has 745 left before bolt replacement,check outdoor heat pump,check electrical delivery system,check electrical absorption system 40/5mfd(reading 40/5.02 mfd),check fan motor(good)check compressor(installed start electrical absorption system SPP8),check condenser coil(clean),check defrost control board,check refrigerant pressure 65/190 R-22,suction line temperature48F,suction saturation temperature 38F,superheat 10F,liquid line temperature 84F,saturation liquid temperature 97F,sub cooling 13F,check all electrical connections and tighten all loose connections, check all cooling, system is cooling and operational


BARRY B.

BARRY B. Job Checkin

Came out today and performed system tune up on a Goodman heat pump system,check blower motor,wheel,and assembly(okay),check electrical absorption system 10mfd(reading 9.8mfd),check air filter(clean),check evaporator coil(clean),flush drain pan,ez trap,and condensate drain line,check condensate pump(pumping good),uv light has 745 left before bolt replacement,check outdoor heat pump,check electrical delivery system,check electrical absorption system 40/5mfd(reading 40/5.02 mfd),check fan motor(good)check compressor(installed start electrical absorption system SPP8),check condenser coil(clean),check defrost control board,check refrigerant pressure 65/190 R-22,suction line temperature48F,suction saturation temperature 38F,superheat 10F,liquid line temperature 84F,saturation liquid temperature 97F,sub cooling 13F,check all electrical connections and tighten all loose connections, check all cooling, system is cooling and operational


Raymond C.

Raymond C. Job Checkin

Installed new moen cartridge


TED W.

TED W. Job Checkin

PLUMBING INSPECTION