JON B.

JON B. Job Checkin

Arrived to find system low on charge 410A. Custo.er opted for recharge only. Added 2 5 lbs 410A and tested operation.


JON B.

JON B. Job Checkin

Arrived to find system low on charge 410A. Custo.er opted for recharge only. Added 2 5 lbs 410A and tested operation. Pressures 150/330, SH 18F, SC 11F, 20F delta T. System back on line. Job complete. There is no warranty on refrigerant.


ADAM O.

ADAM O. Job Checkin

Men’s bathroom toilet filling very slowly and not filling bowl after flush. Minor rebuild on toilet with one year parts and labor warranty. Toilet now filling and flushing properly at this time. Advised to put water into unused shower once a month.


ALEX B.

ALEX B. Job Checkin

two piece minor rebuild upstairs hall and master bathroom and main floor powder room also repaired moen tub shower faucet posi temp (replace cartridge) upstairs hall bathroom


TED P.

TED P. Job Checkin

Found toilet leaking from bolt in tank, installed tank to bowl checked for leaks all good


COREY J.

COREY J. Job Checkin

Completed diagnostic Found chattering contactor at airhandler intermittently allowing electric heat to operate. Went over options with customer Replaced contactor and tested operations All checks ok at this time


ADAM O.

ADAM O. Job Checkin

Snaked basement and main floor toilets with K-6 auger. Toilets are flushing now. Recommend replacement of the toilets. No warranty on toilet stoppage.


COREY J.

COREY J. Job Checkin

High voltage wire burned up at air handler Respliced wiring and tested ops All ops ok at this time


JON B.

JON B. Job Checkin

Arrived and replaced heater kit in air handler. Tested operation. All checks ok at this time. System back on line. Heat amps 10kw 41.03 amps. 47F temp rise. PLEASE CHANGE CHARGE OF 781.00 IN PAYMENT HISTORY TO DEFECTIVE PARTS INSTEAD OF WARRANTY. IT WONT LET ME CHANGE IT.


JOE L.

JOE L. Job Checkin

Installed new 8” frost proof hose bib on front side of home.


BILL H.

BILL H. Job Checkin

I preformed a water line repair in the ceiling of the bathroom. One year warranty between all three fittings.


JESSE W.

JESSE W. Job Checkin

Upon arrival replaced condenser motor, with correct Oporto as needed, also replaced defective, Condenser fan blade as well checked operation, system online at this time.


Brian J.

Brian J. Job Checkin

Came back out to replace condensor fan motor , replace fan motor and tested ok , however the housing and the fan it self is lose causing it to make a weird sound customer is aware gave estimate to replace fan . Also recommended condensor coil to be chemically clean price# 311.00 System operational.


Brian J.

Brian J. Job Checkin

Number of Systems:1 SOLD HSP002 Equipment Age:1993 Came out to performed promo evaluation and sold HSP002, check air filter customer will change ASAP , flush condensation drain pan and line recommended ez trap. Check heat exchanger (ok) flush condensation drain line , check all electrical wires and components,blower motor and wheel assembly dirty, recommend duct cleaning , fan and compressor within spec , replace energy adsorption dual capacitor (50/5) mfd , also hose off condensor as a one time courtesy , explain to customer about refrigerant being phase out , system operational. Pressures # 60/200 Temperature split 20 degrees Model and Serial #'s in SMAC: Y/N Freon: R22 or R410a Metering Device: Fixed or TXV Required subcooling: _____F Supply Air D/B: _____F Supply Air W/B: _____F Return Air D/B: _____F Return Air W/B: _____F Indoor Delta T Target Range: Capacity Check: ____F W/B Delta T:_____ Suction Pressure PSIG: Suction Line Temp:


Jim M.

Jim M. Job Checkin

Performed yearly evaluation. Flushed Water Heater. Replaced hot and cold stems in powder room faucet. 1 year warranty. Handles were slightly broken before I started. Snaked master lavatory.