Joseph R. Job Checkin

During today’s visit, found system not operating at all. Found the thermostat locked. The thermostat is set to cool to 50°. Unable to unlock thermostat. I found both return register filters dirty and clogged due to construction. I found water in the SS2, indicating that the system was icing over and shutting itself down due to poor airflow. I removed the 20 x 25 x 1 filters from the return grills and installed a 20 x 20 x 1 filter at the unit. After emptying out the SS2, The system turns on and runs. The system operates normally after restoring proper airflow. The customer is advised to keep the filters changed regularly. The customer is advised to replace the return grill register filters, and remove the 20 x 20 x 1 filter that I installed today. The customer is advised to keep the thermostat setting at 70° instead of 50°. Photos attached. There will be a balance for today’s visit of $120.


Alex S.

Alex S. Job Checkin

Warranty- Connected drain and changed the dirty 16x20x1 filter System is now cooling properly Pics uploaded