GREAT SERVICE

THE GENTLEMAN THAT CAME OUT WAS GREAT THE LADY IN FRONT WAS GREAT CANNOT SAY ENOUGH GOOD ABOUT THIS CO AND EMPLOYEES

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt and courteous

Arrived in time. Handled the issue and was very courteous.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

the tech was great I am very happy with this company

  • Overall Experience
  • Quality
  • Price
  • Convenience

Honest, professional, helpful technician. Great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for austell, ga

Jordan E.

Jordan E. Job Checkin

Performed single system heat maintenance 4 20x20x2 filters were new cleaned flame sensor and pressure tubes tested all electrical components and connections all systems oper Properly at this time customer states lobby has high air flow and stays cold recommended relocating thermostat to lobby near return to allow system to properly condition this area also please note thermostat was set to cool mode upon arrival


Jordan E.

Jordan E. Job Checkin

I completed a single system heating maintenance. I replaced 1-16x25x1 filter. I checked the amp draw on the blower motor and inducer motor. I cleaned the flame sensor and checked the igniter. I checked safeties and confirmed proper sequence of operation. The system is currently heating at manufacturers specifications.


Alex S.

Alex S. Job Checkin

8 system Commercial PM 2nd visit- Checked heating operations of all package systems. Replaced 2-20x35x2, 4-2025x2, 1-18x25x1, 4-20x25x2, 2-20x20x2, 2-15x20x2,1-14x25x2, 4-20x25x2, 2-15x20x2, 1-14x25x2, 20x35x2, 4-20x35x2, 12-20x25x2, 1-18x25x1, 2-20x20x2, 4-15x20x2, and 2-14x25x2 filters, Checked capacitor outputs and amp drawls, Inspected heat exchangers, Checked delta T, triggered safety switches, Cleaned flame sensors, Cleaned burners, and cleared drain line. Systems are operating properly at this time. Roof access in the back Need to bring 2-A36 belts, AX36 belt, BX50 belts next visit


Jordan E.

Jordan E. Job Checkin

Installed one supply grill 4 x 10. Install one return grill 14 x 20.


Jordan E.

Jordan E. Job Checkin

Filter was stuck in with masking. Pool filter out. Make sure filter will come in and out.


Jordan E.

Jordan E. Job Checkin

Installed t6 thermostat 3 10x6 and 1 14x6 supply grills


Jordan E.

Jordan E. Job Checkin

Performed 2 system heat maintenance both 16x25x5 filters were still in good condition tested safety’s cleaned flame sensors and pressure tubes checked electrical components and connections inspected gas and exhaust supply lines all systems operating properly at this time


Jordan E.

Jordan E. Job Checkin

I completed a single system heating maintenance. I replaced the 16x25x1 filter at the furnace filter rack. I cleaned the flame sensor and igniter. I checked the amp draw on the blower motor and inducer motor.


Jordan E.

Jordan E. Job Checkin

Warranty install. We need to come back to install grills and smart thermostat now that the Sheetrock work is completed is the basement. We installed a basement system for the customer.


David J.

David J. Job Checkin

Transformer and control board replacement. Installed 1-16x25x1 filter


Alex S.

Alex S. Job Checkin

2011 Lennox furnace not working because of a shorted Transformer and control board. Will be ordering board from supplier, pics and quotes uploaded Also bring a 16x25x1 filter


Jordan E.

Jordan E. Job Checkin

Need to reschedule spoke with owner of the house. Tenant is not responding to her. She has no idea what time she will be home or if she is coming home today.


Jordan E.

Jordan E. Job Checkin

I installed the high limit switch and did a maintenance on a one system gas furnace I looked at all the low voltage blower motor and cleaned the flam sensor off and changed the 16x25x1 filter system is running and operating like it should be at this time


Jordan E.

Jordan E. Job Checkin

The high limit switch is bad and needs to be replaced temporarily fixed it for they could have heat for right now


Michael  J.

Michael J. Job Checkin

Performed single system, one time maintenance. Replaced 16 x 25 x 5 filter. Cleaned flame sensor. Inspected electrical connections and components. Treated return with lemon, scented sanitizer and wiped down surfaces. Also added sanitizer to the condensate pump. Used garden hose to wash grass from outside unit. Inspected thermostat operation. Unit is operating properly. Filter was very dirty and technician recommends replacing filter more often. A dirty filter will cause a lack of performance..