3 system CCM- Checked heating operations of Basement 2022 Rheem, 2022 Main level Rheem and 2016 Master Rheem heat pumps and air handlers. Replaced 14x20x1, 2-16x20x1 filters (BRING 2-16X20X5 FILTERS NEXT VISIT), Checked capacitor outputs and amp drawls, Checked refrigerant levels and auxiliary heat, Triggered safety switches and defrost modes, Checked delta T, and cleared drain lines. Systems are operating properly at this time. Pics uploaded Sending qoutes for surge protection, and air/surface cleaners


Jordan E.

Jordan E. Job Checkin

I completed a two system heating maintenance. I replaced 1-18x18x1 ,1-14x14x1 and 1- 20x25x5 media filter. I checked the amp draw on the blower motor and heat strips for upstairs unit. I cleaned the flame sensor and igniter on the main floor system. I checked the amp draw on the blower motor for main floor. I checked the refrigerant charge, these defrost cycle and checked all electrical components on upstairs heat pump. I checked all safeties and confirmed proper sequence of operation. Both systems are currently heating at manufacturers specifications.


David J.

David J. Job Checkin

Performed 2 system heating maintenance. Replaced 1-14x25x1 filter and 1-16x25x5 media filter. Cleaned flame sensors and checked capacitor for upstairs unit. Checked burners and heat exchangers. Leveled main floor system so that it wasn’t leaning to back corner as much. Checked all operations and both systems working properly.


David J.

David J. Job Checkin

Performed 2 system heating maintenance for natural gas furnaces. Replaced main floor 20x25x5 media filter, upstairs 16x25x5 media filter still in good condition. Cleaned flame sensors, checked blower motor amperage, inspected burners and heat exchangers. Both furnaces clean and operating properly.


David J.

David J. Job Checkin

Performed 2 system Heat maintenance. 2 natural gas furnaces. Both filters have been replaced recently, left new ones with customer. Cleaned flame sensors, checked capacitors and blower amperage. Checked burners and heat exchangers. Both furnaces clean and operating properly.


Alex S.

Alex S. Job Checkin

Replaced reversing valve for 2020 right side Rheem heat pump, vacuumed system and added 6lbs of refrigerant. System is now working properly, 20x20x1 pics uploaded. Part is still under manufacture warranty so labor plus refrigerant was only charged. 1yr warranty on labor but not on refrigerant.


Michael  J.

Michael J. Job Checkin

Reversing valve has leak at brass body. Unit has no refrigerant. Refrigerant was used for leak search. Photos as well as a video of the leak have been uploaded. Estimate has been created and sent to the customer. Our office will schedule a return visit for installation of the reversing valve once we have received it.


Michael  J.

Michael J. Job Checkin

Performed maintenance on both HVAC systems in the home. Replaced 16 x 20 x 5 filter for living room/left side of house. Replaced two pieces of 14 x 14 x 1 filters for the master bedroom and upstairs bonus room system. Both of the systems are currently operating properly. However, there has been an issue with the upstairs bathroom, resulting in the removal of sheet rock and insulation to the attic. The home owner had to personally put a plastic as a barrier to hold in the heat. Now that the plastic is in place things have improved somewhat however, their systems are most definitely operating significantly more than they normally would, if the insulation and sheet rock were in place.


Michael  J.

Michael J. Job Checkin

Warranty customer has parts and labor. Last maintenance and filter change was performed October. Filter is 1 inch and today was dirty enough to restrict airflow and cause the furnace to reach the high limit at times. Replaced filter 16 x 25 x 1 and testing system operations. Customer would like recommendations for duct cleaning company as well as estimate for filter change only in between maintenance visits.


Michael  J.

Michael J. Job Checkin

Performed single system heating maintenance. Inspected electrical connections and components along with zoning. Cleared and treated condensate drain line. Verified function of emergency heat strips. Interior cabinet of air handler is clean. Checked refrigerant levels as well as defrost cycle of outdoor unit. 16 x 20 x 5 filter is still acceptable. Customer will replace in spring. System is heating properly.


Jordan E.

Jordan E. Job Checkin

I completed a two system heating maintenance. I replaced 2-16x25x1 filters. I cleaned the flame sensors and igniters.I checked the amp draw on the blower motors and inducer motors. I checked all electrical components and safeties. I confirmed proper sequence of operation. The systems are currently heating at manufacturers specifications, both furnaces are 19 years old and showing age. The coil and ac here recently replaced for the main floor. Filter sizes are still the same.


Jordan E.

Jordan E. Job Checkin

I completed a single system heating maintenance. I replaced 1-14x25x1 filter inside the furnace. I cleaned the flame sensor and checked the igniter. I checked the amp draw on the blower motor and inducer motor. I checked the capacitor and checked all safeties. I confirmed proper sequence of operation. The system is currently heating at manufacturers specifications.


Jordan E.

Jordan E. Job Checkin

I completed a single system heating maintenance. I replaced 1-20x20x1 filte. I checked the amp draw on the blower motor and heat strips. I checked the amp draw and capacitor on the outdoor unit. I test the defrost cycle,I tested all safeties and confirmed proper sequence of operation. The system is currently heating at manufacturers specifications.


Alex S.

Alex S. Job Checkin

1 system CCM- Checked operations of 2019 Carrier heat pump/air handler. Replaced 20x20x1 filter, Checked capacitor outputs and amp drawls, Checked refrigerant levels and auxiliary heat, Triggered safety switches and defrost mode, Checked delta T, and cleared drain line. System is operating properly at this time. Pics uploaded


Alex S.

Alex S. Job Checkin

3 system CCM- Checked heating operations of 2012 Ruud furnaces. Replaced 14x25x1, and 2-20x25x1 filters, Checked capacitor outputs and amp drawls, Inspected heat exchangers, Checked delta T, triggered safety switches, Cleaned flame sensors, Cleaned burners, and cleared drain line. Systems are operating properly at this time.