Jordan E.

Jordan E. Job Checkin

Upstairs unit. Filter needs to be changed next visit. Clean drain. Checked all electronic components. Checked amps on heat strip and blower motor. both test fine. Heat pump.performance, as it should. main level furnace. Filter need to be changed next visit. Clean drain. Checked all electronic components. UV light working. Checked amps on draft inducer motor and blower motor. Both test fine. Checked all safety switches. All test fine. Furnace running as it should. Master bedroom unit. Filter we need to be changed next visit. Clean drain. Checked all electronic components. Checked amps on blower motor and inducer motor. Both test fine. UV light test good. All three heat pumps running as they should.


Jordan E.

Jordan E. Job Checkin

I check mini split. Unit is performing all it can do 12,000 BTU producing 155° air.


Michael  J.

Michael J. Job Checkin

Mini split startup. Pressurized and tightened flairs. System is now operating properly.


Jordan E.

Jordan E. Job Checkin

When I arrive unit had warning, dirty filter. Checked filter and found filter extremely dirty. Put in a 1 inch filter temporary . Customer says he has 5 inch filter on the way will replace it. In the next couple of days. Heat pump performance as it should.


Jordan E.

Jordan E. Job Checkin

Change filter. 16 x 20 by one. Clean drain. Checked all electronic components. Checked amps on heat strip and blower motor. Both taste fine. Checked amps on compressor and fan. Both test fine. Unit low on refrigeration a half a pound. Added refrigeration. Customer signing up for maintenance program.


Jordan E.

Jordan E. Job Checkin

I completed a single system heating maintenance. Customer had recently replaced the media filter and it is still in good condition,it will need to be replaced in the spring.I cleaned the flame sensor and igniter. I checked the amp draw on the blower motor and inducer motor. I checked the capacitor and confirmed proper sequence of operation. The system is currently heating at manufacturers specifications.


Jordan E.

Jordan E. Job Checkin

I arrived and discussed issue with customer.system had already completely thawed out. I turned the system on in cool mode and found the system slightly low on refrigerant. I added just under one pound of 410a to get pressures close to factory subcool. The temperature dropped today and we are below manufacture specifications for a straight ac unit. I discussed this with the customer a I do suggest an electronic leak search on the spring maintenance. Customer will keep an eye on the system performance if they have to use cooling again. Customer is a maintenance member and got the one pound of refrigerant free.


Jordan E.

Jordan E. Job Checkin

Warranty- found water at float switch again. I vented off the clean out tee to improve the draining of the system. Drain line was clear and unit is pitched toward the coil drain. System is currently draining out correctly atpnd no water is draining into the float switch.


Michael  J.

Michael J. Job Checkin

Warranty maintenance Found SS one float switch with water in it, preventing outdoor unit from operating. Technician did test, capacitor, and compressor and components are all good. Technician added PVC union to the condensate drain line and cleared drain line with vacuum. After clearing drain line and removing water from float switch system operations returned to normal.


Jordan E.

Jordan E. Job Checkin

Replacement of furnace control board labor only


Michael  J.

Michael J. Job Checkin

Downstairs furnace control board is no good. Equipment was registered by Greg. Parts are under warranty. New board will be ordered and our office will schedule a return visit to install control board once we have received it.


Jordan E.

Jordan E. Job Checkin

Clean flame sensor.


Alex S.

Alex S. Job Checkin

No fee- 2015 Trane air handler not working because of a shorted ECM blower motor. System is also out of warranty, customer will be thinking about options with motor replacement and a full system replacement. Pics, quotes uploaded. 20x24x1 I also offered a membership plan for discounts if repairs are done


Jordan E.

Jordan E. Job Checkin

Completed single system cooling maintenance. Replaced 20x20x1 filter,cleared drain line and checked all electrical components on the indoor unit. I cleaned the outdoor unit,checked the charge and checked all electrical components on the outdoor unit. System is currently cooling at manufacturers specifications.


Jordan E.

Jordan E. Job Checkin

Performed 1 system cooling maintenance did not have a 20x25x1 filter informed customer they stated they would get one checked electrical components and refrigerant charge all systems operating properly at this time