Technician found that the compressor is grounded. Customer has been a customer for quite some time and would like replacement options as soon as possible.


Alex S.

Alex S. Job Checkin

1 system CCM- Checked operations of 2019 Rheem HP/AH. Replaced 16x20x5 filter, checked capacitor outputs and amp drawls, checked refrigerant levels and auxiliary heat, triggered safety switches and defrost mode, Checked delta T, and cleared drain line. System is operating properly at this time. Pics uploaded


Alex S.

Alex S. Job Checkin

1 system CCM- Checked operations of 2010 Payne heat pump package system. Replaced 14x20x1 filter, checked capacitor outputs and amp drawls, checked refrigerant levels and auxiliary heat, triggered safety switches and defrost mode, Checked delta T, and cleared drain line. System is operating properly at this time. Pics uploaded


David J.

David J. Job Checkin

2 of the duct runs come loose at wye. Reconnected ducts back to system. No charge warranty.


Jordan E.

Jordan E. Job Checkin

Warranty. Arrived and discussed issue with customer. Found outdoor unit in a low pressure lockout. Reset defrost board and system came on. Ran system in cooling mode and system was currently operating at manufacturers specifications. Charge was at 9 degrees subcool,delta t across coil was measured at 16 degree split(supply temp was still dropping but thermometer was reacting slow) and blower fan amps were correct. After talking with patrick there could be an intermittent blower issue. While testing the system the blower never shut off and the system never went into a low pressure lock out. Discussed findings with customer and went over a check list in case this happens again.


Jordan E.

Jordan E. Job Checkin

I performed a heat maintenance on a single heat pump air handler I replaced the 16x20x5 filter I checked all electrical components and temp rise was good I checked the Freon levels and checked the capacitor everything is in good working order at this time.


Jordan E.

Jordan E. Job Checkin

I performed a cooling maintenance on a package unit I checked all electrical components and Freon levels and checked the capacitor and I replaced the 14x20x1 filter everything is in good working order at this time


Chris B.

Chris B. Job Checkin

Back left room which is her craft room has a supply that fell off boot. I reattached flex back to boot. Didn’t notice any other issues with ductwork.


matt@comfortsolutionsair.com

matt@comfortsolutionsair.com Job Checkin

Did not change 16 x 20 x 5 filter still look like it had a couple more months check voltage for fan check voltage for heat strips checked capacitors and checked Freon levels everything looks good also cleaned off outdoor unit with water hose


matt@comfortsolutionsair.com

matt@comfortsolutionsair.com Job Checkin

Did not change 16 x 20 x 5 filter still look like it had a couple more months check voltage for fan check voltage for heat strips checked capacitors and checked Freon levels everything looks good also cleaned off outdoor unit with water hose


matt@comfortsolutionsair.com

matt@comfortsolutionsair.com Job Checkin

Did not change 16 x 20 x 5 filter still look like it had a couple more months check voltage for fan check voltage for heat strips checked capacitors and checked Freon levels everything looks good also cleaned off outdoor unit with water hose


matt@comfortsolutionsair.com

matt@comfortsolutionsair.com Job Checkin

Did not change 16 x 20 x 5 filter still look like it had a couple more months check voltage for fan check voltage for heat strips checked capacitors and checked Freon levels everything looks good also cleaned off outdoor unit with water hose


matt@comfortsolutionsair.com

matt@comfortsolutionsair.com Job Checkin

Change 14 x 20 by one filter checked all capacitors checked fan motor voltage and check Freon levels Everything looked great


matt@comfortsolutionsair.com

matt@comfortsolutionsair.com Job Checkin

Change 14 x 20 by one filter checked all capacitors checked fan motor voltage and check Freon levels Everything looked great