Brandon W.

Brandon W. Job Checkin

Went with qoute on new water heater ($2,116.36)


Brandon W.

Brandon W. Job Checkin

FIREPLACE MAINTENANCE • cleaned the unit from dirt, dust, and debris • inspected the glass • inspected the rope seal on the window • inspected the flue and or combustion chamber • inspected the flu cap assembly • inspected the fan assembly • checked the fans alignment and bearings • inspected the burner assembly for deterioration • cleaned the orifice • cleaned the pilot assembly from carbon build up • cleared the pilot orifice • polished the thermopile • polished the thermocouple • polished the ignitor rod • cleaned and wiped down under the unit • cleaned the glass as best as possible • relayed an ember bed • replaced log-set to manufacturers specs • tested for gas leaks • tested for carbon monoxide • Tested all functions of the fireplace as well as the fan assembly • Turned unit on and tested the thermopile and thermocouple 188mv & 16mv • Inspected the systems performance • Adjusted as necessary for a clean burn Going to do blower pu


Eric R.

Eric R. Job Checkin

FIREPLACE DIAGNOSTIC: The flue cap/ spark arrester is kick and appears to be falling off. I came up and found that the cap assembly is totally fine but the issue is that the actual flue pipe is round and the cap assembly is made for square flues. I was able to retighten the cap into place and as well put some sealant on it to attempt to keep it in place. Due to the assembly being for square chimneys not round, we are not able to guarantee our work for today as well as it would depend on snow loads. If the issue is to occur again I would suggest getting a roofing company involved to get the proper cap assembly for the chimney.


Eric R.

Eric R. Job Checkin

Upon further investigation I found the Lennox brand mini splits unable to handle heating demand necessary for Lake Tahoe climate. So only Mitsubishi brand mini Split was quoted


Eric R.

Eric R. Job Checkin

Working up mini Split quote with engineering department Monday and will email quote over to customer next week


Eric R.

Eric R. Job Checkin

Performed mini split estimate for customer Performed Home fan maintenance: -removed fan cover -cleaner motor -cleaned inner fan casing -cleaned outer fan casing -cleaned fan blade -reattached fan cover -Cycled Unit Customer mentioned that he thinks performance of unit has deteriorated over time and was hoping maintenance would improve it. I informed customer that fan is very basic and made a motor and fan blade. Cleaning it annually is important for longevity but will not drastically increase efficiency or running ability of unit. If customer thinks unit is running poorly I recommended calling quietcool to check on warranty status of unit.


Eric R.

Eric R. Job Checkin

Arrive and install Fireplace Remote homeowners have already paid for. Cycle on unit with new remote and teach homeowners the operation of the ON mode, the thermostat mode, and the off mode. Hang the remote on the wall where the old thermostat used to be. Fireplace is up and running. I leave the pilot lit today.


Eric R.

Eric R. Job Checkin

He needs to discuss it with his wife and get back to us


Eric R.

Eric R. Job Checkin

Bringing the information back to Andrew so he can get eyes on it as well to build the estimate accurately


Eric R.

Eric R. Job Checkin

FIREPLACE DIAGNOSTIC. Arrive and homeowners explain that the unit is working sporadically. The pilot light never shuts off on them but the burner will rarely come on when either of the switches, under the unit or from the thermostat on the wall. I find the master switch underneath the unit to be working intermittently as well as the wall thermostat to not cycle the unit on at at all unless jumped through. Check milovolt reading on thermopile- 538mV and 180 with burner on, thermopile is giving good readings slightly weak but the burner should be able to operate with anything above 150mV. The thermostat and the master switch were not designed for millivolt switching like the fireplace needs in order to work properly. Recommend first a replacement remote with a timer function that is a proper Millivolt switch as well as annual maintenance on the fireplace to monitor its health and keep it in good shape and clean/decorated. Homeowners like the remote with a timer option so I order the rem


Eric R.

Eric R. Job Checkin

Water heater quote includes all equipment, labor, taxes and applicable code upgrades.