Chris was an excellent technican, He was able to troubleshoot, diagnose and resolve the situation without me spending a boatload of $$$
Chris was very thorough and let me know what he was doing for you he tuneup check
Always a great experience with the A Team:).
I have used A team for many years and have been pleased with their consistent quality service!
Love the A-Team! Have kept my HVAC system in tune for 5 years now. My tech is very thorough and transparent. No up selling either, but honest about what is required vs. recommended. Highly recommend.
Response from A-TEAM SERVICES:
Thank you for taking the time to respond to Angelo's review request. We use this as a training mechanism - could you please provide additional information as to what he could have done to improve his service to have earned a 5 star review from you.
Trane XR14 with no cooling due to weak dual run capacitor. Replaced component and verified manufacturer-specified superheat and subcool levels.
Daikin DX13SA condenser coil clogged with debris. Performed full cleaning to restore heat rejection and improve cooling efficiency.
High head pressure on Heil Performance Series condenser traced to weak fan capacitor. Replaced part and pressures returned to normal.
Removed failing split system with refrigerant leaks. Installed new matched components, verified refrigerant charge, and confirmed airflow met design specifications.
Payne PA13NA air handler leaking water due to blocked drain line. Cleared algae buildup, flushed line, and restored proper condensate flow.
Bryant Legacy condenser tripped breaker due to compressor winding resistance issues. Installed hard-start kit to reduce inrush current and improve reliability.
Installed variable-speed system to replace outdated fixed-speed model. Verified airflow balance, humidity control, and quiet operation throughout the home.
York LX Series was short cycling. Thermostat anticipator was set incorrectly. Recalibrated settings, tested cycles, and restored normal operation.
Installed a 3-ton 16 SEER2 condenser and matching air handler today. I pressure-tested the refrigerant lines at 350 psi, vacuumed the system below 500 microns, and charged it to factory specifications with R-410A. System passed all startup tests.
Performed a full AC tune-up including drain line flush, electrical inspection, refrigerant check, and evaporator coil cleaning. I also tested static pressure across the system and found it within manufacturer specs, ensuring optimal efficiency for the cooling season.
Made a service visit to one of our regular clients in Alpharetta's tech corridor. Their Lennox EL296UH090XV36C furnace showed pressure switch error. Inspected venting system and found partially collapsed flex duct. Replaced damaged section and verified -0.88 inches WC draft pressure.
On location in Alpharetta resolving a no-heat complaint on a Trane S9V2-VS furnace. Found corroded flame sensor and weak hot surface igniter. Replaced both components (part #IGN00141 and FLM00142). Measured 3.8 microamp flame signal and verified proper ignition sequence.
I arrived at a home in the Avalon neighborhood of Alpharetta, GA, for a heater repair job. The homeowner reported that the furnace was running but not producing enough heat. After inspecting the system, I found a clogged air filter and a faulty limit switch. I replaced the switch, installed a clean filter, and tested the system to ensure proper heating. The customer was pleased with the quick fix and noticeable improvement in warmth. Contact us for expert heater repair services!
In Alpharetta, GA, I repaired a Trane XR95 furnace that was short-cycling. After inspecting the flame sensor, I cleaned off the buildup and tested the system. I also checked the blower motor for proper function. Once done, the furnace ran smoothly without any interruptions.
Today, I performed routine maintenance on a Carrier Infinity heat pump in Alpharetta, GA. This involved cleaning the outdoor coils, checking refrigerant levels, and inspecting the reversing valve. I tightened electrical connections and ensured the defrost cycle was functioning properly. Everything was operating efficiently after the service.