Have any feedback for us? We'd love to hear it! Call us at (405) 888-5253 and let us know how we are doing.
Great service. They did what was asked quickly and at a fair price.
They got a crew out the same day to fix a complicated problem.
Kressy explained in detail the reason why I was having the problem and what to do to prevent it from happening again. Courteous, thorough, and reasonably priced service.
I can't believe my air is running again! I am so thankful for such great service and honesty. I will definitely be referring to everyone needing services.
Me. Kressy Davis troubleshooting skills and knowledge of the air conditioning systems are outstanding.
We had an emergency last night at one of our restaurant locations I called everyone around town couldn't find a single company to help us. Then I came across this company. Jason helped us from beginning to end! The job is complete we have working air and our clients are very happy. Jason will be doing our PMs and reactive work moving forward. Thank you!!!
Cleared clogged drain and added algae tablet to drain pan Filter was dirty so I changed filter with customers filter Drain flowing
All returns are in stalled all door returns are installed except 174 no door used 20 feet of 4 in flex duct Customer needs you to find supply grills inside measurement 6x18 and quoted price.
Charged system and its cooling for now
Old mercury thermostat finally stopped working. Replaced thermostat with Honeywell pro thermostat. Check refrigerant charge and was system was low. Added 1 lb of R-22 to for system efficiency and to allow system to run without excessive heat build-up.
New furnace, coil, condenser, and thermostat comes with 10yrs parts and 10yrs labor warranty Strap duct work the best we can
12.5ton unit 3phase 240 Heater 41 wide 55 tall 42 deep Condenser is leaking refrigerant Customer wants quotes on replacement
40/5 capacitor reading 36.94/4.84 out of tolerance recommend replacing Fan amps running 0.48 max per data plate is 0.50 that’s high could be due to capacitor Compressor amps running 7.29 max per data plate is 14.1 that’s good Heat pump was covered in vines, customer cleared vines and j washed the best I could System is low on 410a Found leak inside of coil recommend replacing Checked wire connections on heater and everything is firing right up and heating as good as it can with refrigerant issue New coil comes with 5yrs parts and 2yr labor We will replace existing coil and refill system with 410a Will install new 40/5 capacitor Installed new coil and new capacitor 40/5 and charged system
Meeting with customer for commercial service work.
Blower capacitor 5uf reading 3.9 is out of tolerance recommend replacing Coil is rusty and I couldn’t get the complete door off but the part of the door I was able to open I did and found a leak with my leak detector.. I can’t find exactly where it is but my detector went off as soon as I got close to the inside of the coil Compressor and fan motor running high amps, capacitor is good to both Only leaves that the compressor and fan motor are working but are in their last leg System is also low on refrigerant r22 because of leak picture of charge on file I recommend a system replacement the condenser is so old the name plate is completely worn You have a leaking coil which we would have to take furnace out to get out because the coil is above the doorway Washed condenser 16x20x1 filter needs changed I didn’t have one on truck
Cleared clogged drain Water had been draining down thru the system System has bad rusting development across heat exchanger And combustion chamber
Lawn guys broke 2wire at unit Rewired 2wire and replaced 5amp fuse in furnace System is cooling
Bad 35/5 capacitor Changed capacitor and checked fan amps and compressor amps
Really tight space will add time onto job 1 thermostat is gonna be tough to get to but I think it can be done 13 Seer condenser attached to a 92 model furnace and coil Recommend getting into something better efficient with variable speed motors to help control zones more efficiently