2331 Whitfield Industrial Way
Sarasota, FL 34243
941-739-1511

Local Reviews
for sarasota, fl

Rated 4.9 out of 5 stars based on 878 customer reviews

Excellent service and professionalism

Very pleased with Brandon’s thoroughness and expertise. Very knowledgeable, professional and kind.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thorough Service

Thorough service and great knowledge of my LG system.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Very detailed

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good job on routine service

Came on time, very polite checked everything and made recommendations, well done.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Upset Brandon was fine

I think he did a good job But I have a real problem with the information he gave me about static or whatever. I am not happy to hear that after spending 14,000.00 plus that you did not install the proper ducts or whatever, I also noticed that I was told a wifi thermostat was going to be installed and it was not done Now I am wondering what else you didn't do I am not going to rate him because he didn't sell me the system and I don't think he installed the system so he was not the one that didn't install the new thermostat and not the one that didn't have the proper duck work installed. I have gone from being very positive about the company to vary unsure about the company I am extremely upset and disappointed Loren Hoch

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

We're staying with Air Now

Brandon was a pleasure to deal with and Air Now is lucky to have him. As I've said many times a company is only as good as its employees. We have renewed our service contract because of him.

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent service

great guy and great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very quick.

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Competence

Timely and informative technician

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick response and repairs completed

We are super pleased with the quick Service response, knowledge of the technician, diagnosis and immediate repair process. Mr. Rollins was very polite and professional. He gave a clear explanation for the repairs needed. We are surprised that under warranty we had an expensive manufacturer repair.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly, Highly skilled air conditioner service

Thomas is a true professional, I highly recommend him and AIR NOW

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for sarasota, fl

Dierk J.

Dierk J. Job Checkin

Arrived to a maintenance on 2mini split systems. Gree system is for the office and the LG is for the main house. I cleaned and flushed the evaporator coils with clear and water, flushed the drain lines with cleaner and water. The systems are working great at this time. Thanks for using air now for all your air conditioning needs. Tim would like Daniel to text him tomorrow as far as the renewal’s on the contracts. He has questions on the monthly plans. He maybe selling the building this year.


Brandon P.

Brandon P. Job Checkin

AH Cleaned and treated drain line Looked over low and high volt components Got temp splits and static pressure readings Checked heat Checked filter needs replaced Installed sm pan treatment Recommended Uv system CONDENSER Checked pressures Looked over low and high volt components Rinsed coil RECOMMENDATIONS SURGE PROTECTORS PROTECT SYSTEMS FROM SIGNIFICANT POWER FLUCTUATIONS The freeze Protection Lockout Switch, MODEL CPLS, is a temperature sensing control, used to act as a safety against Evaporator Coil freeze up. It is designed to mount on the surface of a 3/4" or 7/8” suction line. Electrically, it is wired in series with the "Y" lead from the thermostat or zone control panel, to the compressor contactor coil or relay. The switch breaks (opens) shutting off the compressor when the temperature of the pipe drops below 37 F. The switch will reset (close), restarting the compressor when the temperature of the pipe rises above 47 F. EWC strongly recommends installing a compres


Dierk J.

Dierk J. Job Checkin

Arrived to do a maintenance on a York system horizontal in the attic. I cleaned and flushed the drain line with water and cleaner. I checked the electrical system. I changed the 16x20x4 filter per plan. I changed the large pan treatment per plan. I cleaned the evaporator coils with cleaner and water. I cleaned the condenser coils with cleaner and water. The system is working great at this time. Thanks for using air now for all your air conditioning needs. Arrived to do a maintenance on a York system horizontal in the attic. I cleaned and flushed the drain line with water and cleaner. I checked the electrical system. I changed the 16x20x4 filter per plan. I changed the large pan treatment per plan. I cleaned the evaporator coils with cleaner and water. I cleaned the condenser coils with cleaner and water. The system is working great at this time. Thanks for using air now for all your air conditioning needs.


Daniel S.

Daniel S. Job Checkin

Need to replace the breakered heat strip, 7.5KW per Ed.


Thomas C.

Thomas C. Job Checkin

Two EcoBee thermostats installed for clients heat pumps. System operations normal.


Jesse P.

Jesse P. Job Checkin

Assurance 1 of 2 York 3:rom ac with 10 kw electric heat Air handler blower meets manufacturer specifications coil clean duct fresh heat strip 38.1 cleaned drain line green clean added small drain pan treatment changed 16*20*4 filter I would strongly recommend installing a ultra violet light kit due to dog hair Condenser all motor amps meet manufacturer specifications refrigerant level meets manufacturer specifications coil clean would recommend installing a new disconnect box and surge protector in newer future Please do a google review today Thanks so much for your business and being the best part of AirNow Jesse Piper Small drain pan treatment 16*20*4 filter


Jimmy C.

Jimmy C. Job Checkin

2,232 Square Feet - Upon Inspection of the attic, Insulation and Ductwork - Increasing the Insulation level (Increasing R Value) would be recommended at this time. Also based the age of the ductwork (2003) - Replacing Ductwork would also be recommended. The ductwork is older (2003) and is sagging in some locations and is loosing its insulation qualities. There have been some improvements made to the ductwork already - Increasing main trunk sizes recently but the rest of the ductwork is from 2003. Mrs. Wood has agreed to Smart Maintenance monthly monitoring for $39.95. $300 credit today. $10/Month credit toward equipment or major repairs. Also $50/year toward filters.


Jimmy C.

Jimmy C. Job Checkin

2,232 Square Feet - Upon Inspection of the attic, Insulation and Ductwork - Increasing the Insulation level (Increasing R Value) would be recommended at this time. Also based the age of the ductwork (2003) - Replacing Ductwork would also be recommended. The ductwork is older (2003) and is sagging in some locations and is loosing its insulation qualities. There have been some improvements made to the ductwork already - Increasing main trunk sizes recently but the rest of the ductwork is from 2003. Mrs. Wood has agreed to Smart Maintenance monthly monitoring for $39.95. $300 credit today. $10/Month credit toward equipment or major repairs. Also $50/year toward filters.


Jimmy C.

Jimmy C. Job Checkin

2,232 Square Feet - Upon Inspection of the attic, Insulation and Ductwork - Increasing the Insulation level (Increasing R Value) would be recommended at this time. Also based the age of the ductwork (2003) - Replacing Ductwork would also be recommended. The ductwork is older (2003) and is sagging in some locations and is loosing its insulation qualities. There have been some improvements made to the ductwork already - Increasing main trunk sizes recently but the rest of the ductwork is from 2003. Mrs. Wood has agreed to Smart Maintenance monthly monitoring for $39.95. $300 credit today. $10/Month credit toward equipment or major repairs. Also $50/year toward filters.


Jimmy C.

Jimmy C. Job Checkin

2,232 Square Feet - Upon Inspection of the attic, Insulation and Ductwork - Increasing the Insulation level (Increasing R Value) would be recommended at this time. Also based the age of the ductwork (2003) - Replacing Ductwork would also be recommended. The ductwork is older (2003) and is sagging in some locations and is loosing its insulation qualities. There have been some improvements made to the ductwork already - Increasing main trunk sizes recently but the rest of the ductwork is from 2003. Mrs. Wood has agreed to Smart Maintenance monthly monitoring for $39.95. $300 credit today. $10/Month credit toward equipment or major repairs. Also $50/year toward filters.


Dierk J.

Dierk J. Job Checkin

Arrived to do a maintenance on a carrier system vertical in closet. I cleaned and flushed the drain line with cleaner and water. I replaced the pan treatment in the drain pan per plan. I checked the electrical system. I changed the filter, 12x24x1, the uv light needs to be moved up in the coil or in the cabinet of air handler. It’s eating the filter. Needs to be ten inches from the filter. The duct work is old and the insulation on the ducts is flaking off and is loosing the r value. Would like to have a comfort adviser come out to give a quote for new duct work. The system is working good at this time. Thanks for using air now for all your air conditioning needs.


Daniel S.

Daniel S. Job Checkin

Walked through the firmware updates with Thomas and calibrated the temperature readings on the wall remotes. The units are operating normally. ESA 1-2 x2 performed today, checked system operations, tightened electrical connections, flushed drain lines and pulled vacuum, rinsed outdoor coils, LGVM monitoring with system operations normal


Joany E.

Joany E. Job Checkin

Diagnosed system found the blower motor failed to run. Replaced blower motor and the system started to runs. The heat and cool operating normal at this time


Jim V.

Jim V. Job Checkin

Duct job for personal home


Jesse P.

Jesse P. Job Checkin

Assurance 2 of 2 Trane over under package heat pump 5 kw electric heat All motor amps meet manufacturer specifications refrigerant level meets manufacturer specifications cleaned evaporator coil duct fresh washed condenser coil start assembly changed inverter the last 24 months filter needs changed spoke with customer and recommend a box of filter and large drain pan treatment was not interested on this visit Please do a google review today Thanks so much for your businesses and being the best part of AirNow Jesse Piper