2331 Whitfield Industrial Way
Sarasota, FL 34243
941-739-1511

Local Reviews
for wimauma, fl

Rated 4.6 out of 5 stars based on 16 customer reviews

Excellent service

Brandon came and did very good job ! He has knowledge of what he supposed to do! Thanks

  • Overall Experience
  • Quality
  • Price
  • Convenience

Routine service

I was very pleased with my service call today. Everything was thoroughly explained. It was a pleasure to do business.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always professional lol

  • Overall Experience
  • Quality
  • Price
  • Convenience

Completed survey as requested

  • Overall Experience
  • Quality
  • Price
  • Convenience

Charged a diagnostic fee for no diagnosis

I was charged a diagnostic fee of $99 and the explanation on invoice says they couldn’t find a diagnosis. Bottom line, I know NOTHING new after the diagnostic charge than I did before, other than it cost me $99 to be told your diagnosis is that you have no diagnosis. Bizarre.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Exceeded Expectations

8am Sunday, booked fir this afternoon. Showed up on time. Arcen wirked to do it right. Get it working as the house was 101° It was a complicated job but he stuck with it. It’s cooling now. I can’t say enough!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Indoor air quality

Great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent customer service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Got what was quoted when it was scheduled. The installers were efficient, capable and kept thing clean. had a wiring problem that was resolved the same day by another tech. All on a saturday.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick and efficient service

They came out within an hour of calling and quickly fixed the issue with my ac unit. I will definitely call them again if a problem in the future.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Estimates

Jim conducted an inspection of the current system and performed the necessary measurements. He was thorough, asked questions and made an assessment on the required system to fulfill our needs. He provided three estimates, all very clear while explaining pris and cons. He answered our questions, and provided us with the necessary materials on which to base our eventual decision.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

Service call was prompt despite it being a weekend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Vince was very informative

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for wimauma, fl

Brandon P.

Brandon P. Job Checkin

MINI SPLIT HEAD Got temp splits Cleaned and replaced filter Looked over low volt components Sprayed and rinsed coil CONDENSER checked pressures Looked over low and high volt components Rinsed coil RECOMMENDATIONS Mini split cleaning tear down of indoor machine to properly clean Condenser coil cleaning tear down of outdoor system to properly clean coil Assurance membership renewal


Jesse P.

Jesse P. Job Checkin

Assurance 1 of 2 Fridgeaire ac package unit 10 kw electric heat All motor amps meet manufacturer specifications refrigerant level meet manufacturer specifications cleaned evaporator coil washed condenser coil changed large drain pan treatment flushed drain pan and drain line talk to customer about possible doing a 4 zone ductless system in next year or so Please do a google review today Thanks so much for your business and being the best part of AirNow Jesse Piper Large drain pan treatment


Joany E.

Joany E. Job Checkin

Upon arrival found the breaker near the package unit tripped. Checked the wire found one leg was loose could possibly cause the breaker to tripped while running on heat. Fixed the wire, flipped the breaker back on and system came on. Checked the heat and cool system is operational and working fine at this time.


Jesse P.

Jesse P. Job Checkin

Assurance 1 of 2 York heat pump package unit All Motor so meet manufacturer specifications refrigerant level meet manufacturer specifications electric back up heat strip 15 amps cleaned evaporator coil with duct fresh washed condenser coil adjusted blower speed due to static pressures .55 after adjustment Talked to customer about drain pan treatment and wasn’t interested at this time Please end hard copy of invoice Please do a google review today Thanks so much for your business and being the best part of AirNow Jesse


Jim V.

Jim V. Job Checkin

QUOTE TO REPLACE HEATPUMP SYSTEM *FINDINGS: -Duct original to home (1989) -Line Set at least 22 years old (has R22 refrigerant in them) -Existing Air Handler “D” cabinet, 49” long -On 2X4’s in drain pan -Homeowner wants to keep his existing Honeywell WiFi thermostat RECOMMENDATIONS: -Replace old refrigerant lines -Replace duct system **OFFERED 0% FINANCING FOR 12 MONTHS-HOMEOWNER NOT INTERESTED IN TRADITIONAL FINANCING**


Brandon P.

Brandon P. Job Checkin

AH Cleaned and treated drain line Sprayed coil Checked filter still good Looked over low and high volt wiring Got temp split and static pressure readings CONDENSER Checked pressures Looked over low and high volt wiring RECOMMENDATIONS Uv replacement bulb Coil cleaning with shampoo tear down of outdoor system to properly clean coil Dynamic Pan Treatments provide dependable, sustained time-release protection for only pennies a day and can be used safely in air conditioner and refrigerator drain pans, dehumidifier water tanks, and other non-potable water retention areas. The pan treatment remains dormant when the drain pan is dry and will continue activating and deactivating as wet and dry conditions change. As it activates, it adds a light, pleasant scent to the air. The freeze Protection Lockout Switch, MODEL CPLS, is a temperature sensing control, used to act as a safety against Evaporator Coil freeze up. It is designed to mount on the surface of a 3/4" or 7/8” suction line.


Jesse P.

Jesse P. Job Checkin

Assurance plus Air handler blower meets manufacturer specifications coil stamped with duct fresh drain cleaned green clean wet dry vac pan cleans with green clean added large drain treatment static .12. Temperature differential 21 degrees Condenser refrigerant level meets manufacturer specifications shampooed condenser coil all motor amps meet manufacturer specifications start assembly in good shape would recommend a start assist and surge protection Please do a google review today Thank so much for your business and being the best part of. AirNow Jesse Piper


Jesse P.

Jesse P. Job Checkin

Assurance lte 1 of 1 Air handler blower meets manufacturer specifications coil clean flier just changed cleaned drain line wet dry vac and primed with water green clean Added drain pan treatment static .41 temp differential 17.2 Condenser all motor amps meet manufacturer specifications cleaned coil refrigerant level meet manufacturer specifications Please do a google review today Thank you for your business and being the best part of AirNow Jesse


Brandon P.

Brandon P. Job Checkin

AH cleaned and treated drain line Sprayed coil Checked filter still good Uv bulb still good Recommended pan treatment declined Looked over low and high volt wiring CONDENSER checked pressures Sprayed coil Looked over low and high volt wiring RECOMMENDATIONS whole home in duct air purifier reduces particulate matter such as dust and dander by improving the performance of your existing filtration system using millions of charged ions effective against odors, VOC's, and inactivates virus in the air The freeze Protection Lockout Switch, MODEL CPLS, is a temperature sensing control, used to act as a safety against Evaporator Coil freeze up. It is designed to mount on the surface of a 3/4" or 7/8” suction line. Electrically, it is wired in series with the "Y" lead from the thermostat or zone control panel, to the compressor contactor coil or relay. The switch breaks (opens) shutting off the compressor when the temperature of the pipe drops below 37 F. The switch will reset (close),


Oliver K.

Oliver K. Job Checkin

Upsized duct from 6" to 7", and adjusted the grills in master bed to the customers liking


Brandon P.

Brandon P. Job Checkin

AH cleaned and treated drain line Changed filter customer provided Looked over low and high volt components Sprayed coil Check Uv bulb still good CONDENSER checked pressures Sprayed coil Looked over low and high volt components RECOMMENDATIONS whole home in duct air purifier reduces particulate matter such as dust and dander by improving the performance of your existing filtration system using millions of charged ions effective against odors, VOC's, and inactivates virus in the air SURGE PROTECTORS PROTECT SYSTEMS FROM SIGNIFICANT POWER FLUCTUATIONS The freeze Protection Lockout Switch, MODEL CPLS, is a temperature sensing control, used to act as a safety against Evaporator Coil freeze up. It is designed to mount on the surface of a 3/4" or 7/8” suction line. Electrically, it is wired in series with the "Y" lead from the thermostat or zone control panel, to the compressor contactor coil or relay. The switch breaks (opens) shutting off the compressor when the temperature of th


Jesse P.

Jesse P. Job Checkin

Assurance 1 of 2 Air handler blower meets manufacturer specifications coil clean 20*25*4 filter costumer supplied cleaned drain line with green clean and hot water


Jesse P.

Jesse P. Job Checkin

Assurance 2 of 2 Air handler blower meets manufacturer specifications coil clean time to change 20*20*4 filter and yearly uv bulb. Drain cleaned wet dry vac green clean primed drain static return,12 supply ,21. 20 degree differential Condenser All motor amps meet manufacturer specifications cleaned condenser coil refrigerant level meets manufacturer specifications Thanks you for your band being the best part of AirNow Jesse


Jesse P.

Jesse P. Job Checkin

Assurance 2 of 2 York heat pump Air handler blower meets manufacturer specifications coil clean was in unable to clean or assess air handler due to stuff in way did change 4 inch 20*20*4 filter but no room for ladder cleaned main drain wet dry Vac and nitrogen Condenser all refrigerant change in specifications all motor amps in spec unable to wash coil back flow pervert on house leaks. System in good heath Thanks so much for your business and being the best part of AirNow Jesse


Jesse P.

Jesse P. Job Checkin

Assurance 2 of 2 Main system Air handler. Blower meets manufacturer specifications coil clean added drain pan treatment cleaned drain wet dry vac green clean and a gallon of water I would recommend a UV light kit for evaporator coil Please contact mr Preczewski about ductwork in guest bathrooms and replacement of ceiling grills Condenser. All motor meet manufacturer specifications refrigerant levels meet specifications coil Cleaned. Added start assist Please do a review today Thanks so much for being the best part of AirNow Jesse Start assist and drain pan treatment