JODY W.

JODY W. Job Checkin

GENERATOR FUEL SUPPLY WAS OFF.


Jamie C.

Jamie C. Job Checkin

REPLACED FAULTY THERMOSTAT.


Robbie R.

Robbie R. Job Checkin

FOUND THE PRESSURE SWITCH DAMAGED GOING TO THE WATER WELL. REPLACED (1) PRESSURE SWITCH. TESTED FOR PROPER OPERATION.


JUSTIN L.

JUSTIN L. Job Checkin

FOUND A DAMAGED FUSE HOLDER. RETURNED ON 12/5/24 TO REPLACE THE 200AMP PANEL AS PER QUOTE. TESTED FOR PROPER OPERATION.


Robbie R.

Robbie R. Job Checkin

RETROFIT (2) FLUORESCENT LIGHT FIXTURES TO LED IN THE KITCHEN. TESTED FOR PROPER OPERATION.


Daniel  H.

Daniel H. Job Checkin

REPLACED LIMIT SWITCH AND TRANSFOMER FOR HEATING SYSTEM.


JUSTIN L.

JUSTIN L. Job Checkin

FOUND BLOWN FUSE ON THE DISCONNECT. RETURNED ON 11/13/24 TO REPLACE THE FUSE BOX WITH A 4-CIRCUIT BREAKER BOX. ALSO INSTALLED (2) 15AMP RECEPTACLES AND REPAIRED WIRING. TESTED ALL FOR PROPER OPERATION.


Miranda C.

Miranda C. Job Checkin

FOUND THE BREAKER TRIPPING DUE TO MOISTURE INSIDE OF THE LIGHT FIXTURE. DRIED OUT THE LIGHT FIXTURE, WHICH ALLOWED THE BREAKER TO STOP TRIPPING. TESTED FOR PROPER OPERATION.


JODY W.

JODY W. Job Checkin

SERVICED GENERATOR INCLUDING CHANGING FILTERS AND OIL. TESTED GENERATOR AND TRANSFER SWITCH FOR PROPER OPERATION.


Jamie C.

Jamie C. Job Checkin

CHECKED A/C UNIT AND REPLACED A BAD CAPACITOR.


Albritton Service C.

Albritton Service C. Job Checkin

TO BILL FOR SERVICE CALL TO INSPECT ELECTRICAL ISSUE. INSTALLED (1) HATER/VENT/LIGHT IN THE BATHROOM DOWNSTAIRS, RETROFIT (1) LIGHT TO LED IN THE LAUNDRY ROOM, AND INSTALLED (1) LIGHT IN THE DOG PEN. TESTED ALL FRO PROPER OPERATION.


Callie M.

Callie M. Job Checkin

INSTALLED A 24 KKW GENERAC GENERATOR WITH A 200A TS


Miranda C.

Miranda C. Job Checkin

CHECKED AC UNIT AND FOUND THE SYSTEM LOW ON FREON, A BAD CAPACITOR, AND THE THERMOSTAT FAULTY. REPLACED CAPACITOR AND THERMOSTAT AND RECHARGED UNIT WITH FREON.


Miranda C.

Miranda C. Job Checkin

CHECKED UNIT THAT WAS LEAKING WATER AND FOUND THE INSULATION WRAPPED AROUND COIL AND DRAIN CLOGGED. CLEARED DRAIN AND MOVED INSULATION.


Daniel  H.

Daniel H. Job Checkin

CHECKED A/C UNIT AND FOUND A BAD THERMOSTAT, BREAKER, AND CONTACTOR, REPLACED PARTS AND RAN SYSTEM FOR PROPER OPERATION