24530 Sperry Dr
Westlake, OH 44145
440-871-3777

Local Reviews
for bay village, oh

Rated 5.0 out of 5 stars based on 513 customer reviews

Great Service

Jason was outstanding

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Company

  • Overall Experience
  • Quality
  • Price
  • Convenience

Nice job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

repair air conditioner

My wife is handling most stuff now and was very pleased with the persons that came. They were friendly and got a new part installed quickly. J

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional, polite and kind.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Yearly check up.

Great service and I learned more about the workings of our furnace, etc. thanks!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Working now

Was on time, unit working now is what mattered. Thx

  • Overall Experience
  • Quality
  • Price
  • Convenience

thorough...professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt...informed...direct and to the point...courteous.

ok

  • Overall Experience
  • Quality
  • Price
  • Convenience

good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

very professional and businesslike

well-done

  • Overall Experience
  • Quality
  • Price
  • Convenience

Courteous & Knowledgeable HVAC Service

Johnathan arrived and promptly set out to work, being careful not to bring in outside dirt after this mornings rain. he promptly performed the service tune up indoors and then tackled the outdoor unit. He briefed me on his findings and gave me a few tips in the process.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for bay village, oh

Marty T.

Marty T. Job Checkin

Found zone one to be powered by transformer either in attic or at zone control and was not hooked up correctly at installation of zone system install had to put both common wires under C of thermostat. thermostats were changed in September and not wired correctly from that point .


Jason J.

Jason J. Job Checkin

No cooling. I found a failed dual capacitor. I replaced it and cycled with proper operation. Upon further investigation I found the fan blade is cracked. I am providing a price to replace the blade and motor.


John J.

John J. Job Checkin

Install class B pipe


Marty M.

Marty M. Job Checkin

System Replacement


Jose M.

Jose M. Job Checkin

$119.95 Each Furnace And A/C Tuneup. Replace #413Sg. “Furnace” T-Stat, 50 Ohms HSI, Flame Sensor, 80% Inducer Assembly, 3.5” W.C. Gas Valve, Burner, 7.5+370 Run Cap Blower Motor, 64* Outside, “A/C Unit” T-Stat, #413Sg, Drain Trap, 70*-50*=20* D-T, Disconnect, 2=40 Amps Fuse, Electrical, Hard Start & 45+5+440 Dual Run Cap, Hose Down, Remove Leaves And Cottonwood, R410A, Blower Motor, Cycled Both Unit, Clean And Check.


Justin W.

Justin W. Job Checkin

System Replacement


Jason J.

Jason J. Job Checkin

Furnace tune up.


Jose M.

Jose M. Job Checkin

Club Boiler Tuneup. T-Stat Found Zone #1, Not Working Need To Follow-Up. Same T-Stat Working On Cooling Mode. Zone #2,#3,#4,#5 Are Working, 180* & 15PSI, Spark Igniter, 80% Inducer, Cycle Pump, Cycled Unit, Clean And Check.


Jason J.

Jason J. Job Checkin

No cooling. Unit low on charge. Due to age and condition I highly recommend replacement. Sean is going to call the customer and schedule an estimate .


Jose M.

Jose M. Job Checkin

Club Furnace And Humidifier Tuneup. Replace Car-0909Wp. T-Stat, 48 Ohms HSI, Flame Sensor, 2-Stage 90% Inducer Assembly, 1.5” & 3.5” W.C. Gas Valve, Drain Trap, 122* & 112*-72*=50* & 40* T-R, Ez-Flex #16, V.S. Blower Motor, 76* Outside, Humidifier Fan Power, Hum-Stat, Drip Tray, Water Valve, Drainline, Cycled Units, Clean And Check.


Besham B.

Besham B. Job Checkin

Customer said unit was frozen up. Cycle unit on to check for evaporators coil was reading 19*. Charge it up to 47* with a sub cooling of 6* and supply air 57* and return air 76*. At tell customer if system low on charge again she will need to do a leak search. At time of dispatch unit is.


Jose M.

Jose M. Job Checkin

No Cooling. Found A Bad Low On Charge Bad Valve Leaking Recommed Replacing 25+ Year Old A/C Unit.


Jason J.

Jason J. Job Checkin

Unit making noise. We found the condenser fan motor has failed. Scheduled for 8-22&8-23 for install.


Jason J.

Jason J. Job Checkin

No cooling. I found the evaporator coil was iced over. I turned off the breaker and cycled the a/c in order to speed up the thawing process. We will need to return and test the unit.


Jose M.

Jose M. Job Checkin

$75.00 Second Floor A/C Tuneup. Replace Bad #20x25x1 Air Filter Suppled. T-Stat, 76*-61*=15* T-R, Drain Trap, Downflow Blower Motor, R410A, Disconnect, 2=40 Amps Fuse, Electrical, 45+10+370 Dual Run Cap, Hose Down, 72* Outside, Cycled Unit, Clean And Check.