Rated 5.0 out of 5 stars based on 4 customer reviews

Winter Emergency

Bay Heating answered my emergency call and the on-call technician was here in good time. He assessed the heating unit from a number of different scenarios to identify the root problem. The part was ordered and will be installed today

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great people to solve problem

I trust and depend on these people to find and solve any problems with the HVAC system.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Rosie

Jose came to do fall heat check. Excellent job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Bay Heating Check up

Bay Heating performed a Check up on our heating system today. The Bay representative was great - very professional and knowledgeable and the work was done expertly and in a timely manner. Highly recommend Bay Heating.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for elyria, oh

Marty T.

Marty T. Job Checkin

Found fuse blown in air handler check for shorts found non-replace fuse total low-voltage amp draw .73 return unit to service


Besham B.

Besham B. Job Checkin

Check thermostat check blower motor change filter flush condensate drain. Supply air 50* return air 67*. Check disconnect 40 amps fuse. Check capacitor 55+5+370 dual run Cap. Cycled unit On the check compressor and fan working. Wash and clean condenser coil. Outdoor temperature 66°. At time of dispatch unit is working.


Marty T.

Marty T. Job Checkin

Found thermostat was blank due to overflow switch in auxiliary drain pan tripped because drain pan full of water removed with shop vac tried calling Jim Price to find out how to turn on dehumidification mode but he is out of town until Monday will consult with him and may need to return to turn on dehumidification mode checked contactor capacitor compressor and fan clear condensate trap checked blower motor and filter unit operating well excessive humidity in home reading 78%


Jason J.

Jason J. Job Checkin

Upon arrival we found a blown five amp fuse in the air handler. I replaced the fuse tested and cycled on emergency heat and it is working fine. We put the unit in heat pump mode and the unit failed at the thermostat. I manually cycled the heat pump and now it is operating properly. Due to the 20° outdoor temperature and recent power outages we’re leaving the unit in emergency heat temporarily. The homeowners care taker is going to put the unit back into heat pump mode once the weather warms up.


Marty T.

Marty T. Job Checkin

Found bad control board. Replaced board. Cycled system operating properly at this time. Thanks Marty and Brian


Brian M.

Brian M. Job Checkin

Upon arrival I found furnace displaying code 23. Pressure switch did not open. No power to inducer due to faulty control board. I brought space heaters out for temporary heat until repair can be completed. Thanks Brian.


Jason J.

Jason J. Job Checkin

Found thermostat set for cooling turn to heat cycle to check OK


Jason J.

Jason J. Job Checkin

Clean pilot burners firebox and controls check all operating on safety controls check pump low-water cut off and water feed cycle boiler to check OK found no problems


Jason J.

Jason J. Job Checkin

Clean burners flame sensor vestibule and controls check all operating and safety controls check blower and motor change filter check all operating and safety controls fired furnace to check OK.


James A.

James A. Job Checkin

Found bad blower motor cust would like estimate scheduled for Tommorow.


James A.

James A. Job Checkin

Perform heating tune up 20 amps on each bank of electric strip heat cycled to check all okay at this time.


Marty T.

Marty T. Job Checkin

Check blower motor and filter change filter clear condensate trap check contactor capacitor compressor and fan cycle air conditioner to check OK


Marty T.

Marty T. Job Checkin

Found filter dirty remove and replace customer supplied cycle furnace to check OK reset limit switch


Marty T.

Marty T. Job Checkin

Check blower motor and filter clear condensate trap check contactor capacitor compressor and fan cycle air-conditioner to check 40° ambient clean condenser coil


Jose M.

Jose M. Job Checkin

Heatpump Tuneup