A/C Inspection

Thanks for keeping the appointment in the middle of a heat wave and then an afternoon thunderstorm. I took off work to be home, so it was very important to keep the commitment. Also it was an important inspection since the system had not been inspected in six years and José convinced me to have one.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for parma heights, oh

Jose M.

Jose M. Job Checkin

No Cooling. Found A Bad 35+5+370 Dual Run Cap Reading 0+0+370, Replace Cycled Unit Fine At This Time.


Jose M.

Jose M. Job Checkin

Club A/C Tuneup. Replace #201Sg. T-Stat, 69*-51*=18* Drain Trap & Pump, D-T, Blower Motor, R410A, Disconnect, 2=25 Amps, Electrical, 45+5+370 Dual Run Cap, Hose Down, 74* Outside, Remove Leaves And Cottonwood, Cycled Unit Clean And Check.


John J.

John J. Job Checkin

AC start up complete


Cory B.

Cory B. Job Checkin

Full System installed


John J.

John J. Job Checkin

System replacement


Jason J.

Jason J. Job Checkin

Air-conditioning tuneup. Condenser coil was washed out. Contactor capacitor and connections were inspected. Condensate drain was flushed and pump was checked. Humidifier bypass damper was closed. Filter was very dirty so I removed and put a temporary filter in for the customer. With the customer supply. Customer is going to investigate replacing the filter on his own. This is an infinity air cleaner. The UV bulb is over one year old and should be replaced as well and the customer is going to investigate replacement. System was bump started and is ready for summertime use.


Brian M.

Brian M. Job Checkin

Checked thermostat. Checked filter. Changed easy flex filter supplied by customer. Flushed out AC trap. Checked temperature drop. 20° temp drop. Checked all electrical connections. Checked contactor. Checked capacitor. Cleaned outdoor coil with hose and water. Cycled system to check. System is operating properly at this time. Thanks Brian. Customer would like to have a Solenoid that was found to be faulty in the heating tuneup. Causing a buzzing and vibrating noise. He would like to have that repair done during the heating tuneup.


Jason J.

Jason J. Job Checkin

Club Furnace Tuneup. “Furnace” T-Stat, 49 Ohms HSI, Flame Sensor, 80% Inducer, Electrical, 3.5” W.C. Gas Valve, Burner, #201Sg, 5+370 Run Cap Blower Motor, 33* Outside, “Humidifier” Not Used.


Jose M.

Jose M. Job Checkin

Club Furnace & Humidifier Tuneup. Replace Ez-Flex #16 & #10Wp Supplied. “Furnace 3-Stage 90%” T-Stat, 46 Ohms H.S.I, Flame Sensor, 3-Stage 90% Inducer & Blower Motor, Electrical, Drain Trap, 92* Outside. “Humidifier” Hum-Stat, Scale Control Insert, Water Valve, Drainline, Electrical, Cycled Unit Clean And Check.


Jose M.

Jose M. Job Checkin

Club AC Tuneup. T-Stat, #201Sg, Drain Trap & Pump, 65*-49*=16*D-T, Blower Motor, Bypass Humidifier Turn Off & Damper Close, R410A, Disconnect & 2=25 Amp Fuse, Electrical, 40+5+370 Dual Run Cap, 77* & Rain, Remove Cottonwood, Hose Down , Cycled Unit Clean & Check.


Jose M.

Jose M. Job Checkin

Replace EZ-Flex #16 Supplied. T-Stat, Drain Trap, V.S. Blower Motor, 2-Stage R410A, Disconnect, 35+5+370 Dual Run Cap, Electrical , 38° & Rain Outside, Clean & Check.


Jose M.

Jose M. Job Checkin

Replace inducer assembly


Jose M.

Jose M. Job Checkin

AC & Furnace Tuneup