24530 Sperry Dr
Westlake, OH 44145
440-871-3777

Local Reviews
for sheffield lake, oh

Rated 5.0 out of 5 stars based on 5 customer reviews

Customer Service

The service rep was on time as promised and very professional and efficient. While the extremely wet conditions under my home in the crawl space prevented him from getting under the house to do a closer inspection, his gas detector unit confirmed the presence of gas, as suspected, and the probable need for repair. So "mission accomplished."

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

This was a follow-up visit to finalize my repair job. Both technicians were on time, courteous and wonderfully efficient. I could not have been more satisfied! Thank you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Our tech was personable and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great servive

Call Jose for good service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for sheffield lake, oh

Marty T.

Marty T. Job Checkin

Change filters per agreement


Brian M.

Brian M. Job Checkin

After testing the area with my gas detector I found at least 2 spots where gas is leaking. Around the antique stove and in the crawl space. Because of all the rain the crawl space is full of water and mud. I was unable to determine exactly where the leak is. My detector was going crazy as soon as I opened the entrance to crawl. I recommend shutting the gas off at the meter for safety. Customer will consider calling a plumber to repair the leak. Thanks Brian.


Jason J.

Jason J. Job Checkin

A/C tune up. Condenser coil was washed out. Contactor, capacitor and connections were inspected. Condensate trap was flushed out. Filter is replaced by the customer. System was cycled with proper operation.


Marty T.

Marty T. Job Checkin

Check blower and motor change filters tighten belt,checked contactor capacitor compressor and fan cycle air conditioner to check OK.


Marty T.

Marty T. Job Checkin

Clear condensate trap check condensate pump checked blower motor and filter check contactor capacitor compressor and fan cycle air conditioner to check OK cleaned condenser coil


Cory B.

Cory B. Job Checkin

Install of humidifier.


John J.

John J. Job Checkin

Humidifier installation


Jason J.

Jason J. Job Checkin

No heat. I found a failed hot surface igniter. I replaced igniter and cycled the furnace with proper operation.


Jason J.

Jason J. Job Checkin

Repair low voltage wire cycle to check, ok.


Jason J.

Jason J. Job Checkin

Com furnace maintenance Changed filters, cleaned burners, checked inducer and blower. Checked blower belt, ok.


Jason J.

Jason J. Job Checkin

Completed furnace tuneup. Flushed trap. Cleaned flame sensor. Checked thermostat. Flushed condensate drain. Cycled system system is operating properly at this time


Jason J.

Jason J. Job Checkin

I found the flue spill switch was tripped. I reset and found the vent is clear but the house is negatively pressurized. Per RT Paul needs to look into adding fresh air to the furnace return.


Marty T.

Marty T. Job Checkin

Found flame sensor dirty also cooling fan broke off of inducer assembly and blower housing not correctly even place furnace 17 years old and in very poor condition replacement needs serious consideration, ASAP.


Marty T.

Marty T. Job Checkin

Clean burners flame sensor controls checked blower motor belt change filters check all operating and safety controls psycho heat to check OK found no problems


Jason J.

Jason J. Job Checkin

No heat. I found the flue spill switch was Tripped. It was possible that the high winds over the weekend caused a backdraft. I inspected the flue pipe and found no blockage. If the spill switch opens again I would recommend adding a 1 foot piece of b vent to the chimney stack.