Ac clean and tune. Checked indoor coil with refrigerant sniffer, no indications found of leak. Cycled system. Checked and cleaned electrical compartment. Tested compressor and fan motors, both tested just outside of caution range. This indicates that both motors may fail and are very worn. Used coil cleaner on condenser coil. Hooked up gauges and checked pressures and temps. Found subcooling low. Indoor coil is at 40 degrees. Found higher indoor temps with higher humidity. Tested split, it was 17 degrees. Condenser coil fins are very worn causing heat to stay in refrigerant. Due to age and condition, future failure is expected. Second opinion recommended. Job complete.