N967 Quality Drive
Greenville, WI 54942
920-750-7138

Job Locations
for greenville, wi


Map of Greenville WI
Julian  D.

Julian D.


Job Checkin

Performed furnace start up; inspected the exhaust and intake PVC ensuring all connections were secured, sniffed the gas line for possible leaks, as well as cycled the system on and checked gas pressures did find that 1st stage would not adjust we’ll have to return to replace the gas valve, also performed a combustion test verifying no CO in the airstream. This system is currently operating normal and heating at 42 degrees at this time. Lastly I wanted to make note I did notice on the maintenance sticker that a previous company had added 8oz of R22 refrigerant to the AC sytem back in 2007 but did not locate nor fix any leaks. I did a refrigerant leak search on the indoor coil and did find a couple solid indicators of a leak on the system. This is a concern for me because that coil sits right above the heat exchanger on this brand new furnace and an AC sytem that is low on charge could form a solid block of ice during the summer months meaning that the condensation would fall on the he