Ac clean and tune. Checked indoor coil with refrigerant sniffer, found two spots that give indications of a refrigerant leak. Cleared drain line. Cycled system. Checked and cleaned electrical compartment. Found contactor and capacitor are very worn and should be replaced. Tested fan motor and compressor, both tested in caution range. This indicates that both of these motors will fail in the near future. Used coil cleaner on condenser coil. Hooked up gauges and tested refrigerant pressures and temps. System is low on charge. Sub cooling is 20 and superheat is 3. Temp split is 13. This system is very worn and fails the inspection for efficiency and reliability. Average life of this unit is 14 years, this system is 21+ years old and in very poor condition. Second opinion is recommended. Future failure is expected. Job complete.