N967 Quality Drive
Greenville, WI 54942
920-750-7138

Job Locations
for kimberly, wi


Map of Kimberly WI
Dan E.

Dan E.


Job Checkin

Furnace clean and tune. Cycled system. Checked heat exchanger. Checked and cleaned flame sensor and burners. Ventor motor has some bearing wear. Igniter is worn, but tested ok. Normal levels of CO and XS air in exhaust. No CO found in airstream. System is worn, but operating normal at this. Job complete.