Completed AC replacement. Reclaimed old refrigerant and removed old condenser and coil. Installed a new evaporator coil in the furnace plenum. Set and leveled a new pad outside and placed new condenser on it. Flushed the existing lineset and reconnected to the condenser and coil. Pressurized the lineset to 325 psi with nitrogen to test for leaks and then evacuated to 488 microns. Released charge and did a complete start up procedure. Thank you for choosing Black-Haak heating. Please take a moment to fill out our online survey.