Ac clean and tune. Checked indoor coil with refrigerant sniffer. Some indications found for possible leaks. Cycled system and found condenser not running with contactor pulled. Found fuse off in fuse box. Cycled and condenser fired. Checked compressor, found compressor lower on ohms, but barely in normal range. Used coil cleaner on condenser. Hooked up gauges and checked pressures and temps. Indoor split was normal. Average life expectancy for this unit is 14 years, this system is 17 years old and showing signs of being worn. System is cooling normal at this time. Major damage to fins on condenser, small leak indications on indoor coil, and compressor low on ohms are all signs that future failure is expected. Job complete.