Furnace clean and tune. Cycled system. Checked heat exchanger. Found signs of rust and corrosion. No visible cracks found. Removed, checked, and cleaned burners and flame sensor. All ok. Checked gas pressures and adjusted to maximize efficiency. Checked electrical connections and clamps. Found normal levels ofmCO and XS air in exhaust. No CO found in airstream. Changed humidifier panel. Cycled humidifier. System operating normal at this time. Cycled air to air system. Checked and cleaned all three filters. Main block filter and pre filters are in good condition. Cleaned filters and all surfaces of unit. Checked fan motors and cleaned fan blades. Checked and cleared drain lines. System operating normal at this time. Ac. Cycled system. Checked indoor coil, ok. Checked electrical compartment. Fan motor and compressor tested normal. Capacitor and contactor ok at this point. Hooked up gauges and checked pressures and temps. Subcooling was 10. Indoor coil temp was 41, indoor temp split was