Hunter D.

Hunter D. Job Checkin

Performed level 2 furnace cleaning. Burners and flame sensor are clean. HeT exchanger looks good. Gas and exhaust levels are normal. No CO detected in the air. I also investigated a no heat. Turns out the furnace itself was locking out, not the thermostat. Furnace would kick out immediately after ignition. I cleaned the flame sensor thoroughly and restarted the furnace. Flame was proven and stayed lit. Unit is operating normal at this time.