2430 Reliance Ave
Apex, NC 27539
919-773-9223

Job Locations
for raleigh, nc


Map of Raleigh NC
Chad B.

Chad B.


Job Checkin

Inoperable Deficiency for Kitchen BHM06392 Beverage-Air SPE72-30M 12004256: On site, customer advised cooler was not operating - Plugged unit in and checked operation - Applied gauges and found system nearly empty - Verified leak is from evaporator coil - Customer wants to charge system - Unit is leaking to fast to top off refrigerant Suggested for Kitchen BHM06392 Beverage-Air SPE72-30M 12004256: Arrived to do quotes repair for 3 door reach in. •disassembled panes and shelving to expose evaporator. Also removed top doors and cold bin. •uninstalled and removed evaporator. •cleaned evaporator area and condensate drain pan •removed old cap tube and filter drier •piped in and mounted new evaporator and cap tube. New evaporator about 1/2” shorter than existing one. New mounting holes needed to be fixed. • replaced filter drier. Added time due to newer one being different than one existing and had to rework the copper plumbing. • pressure tested to 150 psig for 20 minutes • dehydrate