System-main Approx Age of System: 1 Refrigerant Type- R410a Metering Device- Fixed Orifice / TXV SP/HP:145.6/389.5 SLT/LLT:58/106.7 VSAT/LSAT- 51/114.5 Superheat/Subcool-7.1/7.9 Outdoor Entering Air Temp-98 Outdoor Fan FLA- R.5 A.5 Compressor RLA/LRA-R14.1/77. A10/74.06 Contactor Voltage-234/25 Capacitor Rating-45/5 A44.7/5 Indoor Return Dry Bulb Temp-80.2 Return Wet Bulb Temp-67.9 Supply Temp-63.2 Temperature Difference-17 Required Difference-15-22 Blower FLA- 4.7 Filter Sizes – 2-14x24x1 Changed Filters – Y customer changed Blew out drain line: Y Notes-Arrived on site, performed ac tune up. System is operating within specifications, no issues found. Scheduled next tune up date: Jan 11 10-2