30045 FM 2978 Rd.
Magnolia, TX 77354
(281) 651-5484

Job Locations
for montgomery, tx


Map of Montgomery TX
Juan  M.

Juan M.


Job Checkin

System: Carrier Approx Age of System: 7 Combustible Gas Leak Detection Pipe and fittings leak-free: yes Valves and orifices leak-free: yes Carbon Monoxide Testing Walk-around CO: pass 0 /ppm Airside CO: pass 0 /return ppm 0 supply ppm Flue gas CO: pass 25 /ppm Ignition and Combustion Delayed ignition: no Flame disturbance: no Flame discoloration: no Motor Amperages and Capacitors Blower motor FLA: 5 Induced draft/combustion blower motor FLA: 1.3 Capacitor(s): pass or fail/mfd N/A Temperature Rise Rated: 1st 30-60 Actual: 1st 47 Static Pressures Blower speed/cfm: RP .34 /FS .39 /SP .12 TESP: .73 Safety Controls Primary limit test: pass Filter sizes: (2)20x25x1. 12x12x1 Changed filters: no customer will change Scheduled next tune up date: Notes: system was operational upon arrival. Performed tune up and found that customer does not have any kind of overflow protection highly recommend installing so home can be protected from any water damage to the