30045 FM 2978 Rd.
Magnolia, TX 77354
(281) 651-5484

Job Locations
for montgomery, tx


Map of Montgomery TX
Juan  M.

Juan M.


Job Checkin

System- zones Approx Age of System: Refrigerant Type- R410a Metering Device- TXV SP/HP: 106/255 SLT/LLT: 56/78 VSAT/LSAT- 35/85 Superheat/Subcool- 20/7 Outdoor Entering Air Temp- Outdoor Fan FLA- 1 Compressor RLA/LRA-11.5/55.9 Contactor Voltage- 238/26 Capacitor Rating- 70/7.5 actual 69.8/7.5 Indoor Return Dry Bulb Temp- 76 Return Wet Bulb Temp- 68 Supply Temp- 58 Temperature Difference- 18 Required Difference- 15-20 Blower FLA- 5.8 Filter Sizes –2 12x12x1 16x25x1 14x20x1 Changed Filters – N customer will Blew out drain line: N Notes- System- upstairs Approx Age of System: Refrigerant Type-/ R410a Metering Device- / TXV SP/HP: 112/263 SLT/LLT: 49/80 VSAT/LSAT- 37/86 Superheat/Subcool- 13/7