30045 FM 2978 Rd.
Magnolia, TX 77354
(281) 651-5484

Job Locations
for montgomery, tx


Map of Montgomery TX
Ernest P.

Ernest P.


Job Checkin

System- single (2z) Approx Age of System: 5 Refrigerant Type- R410a Metering Device- TXV SP/HP: 116/283 SLT/LLT: 54/78 VSAT/LSAT- 38/91 Superheat/Subcool- 15/13 Outdoor Entering Air Temp- 75 Outdoor Fan FLA- 1.1 Compressor RLA/LRA- 7.6/113.7 Contactor Voltage- 241 Capacitor Rating- 44.4/6.5 (45/7.5) Indoor Return Dry Bulb Temp- 70 Return Wet Bulb Temp- 59 Supply Temp- 48 Temperature Difference- 22 Required Difference- Blower FLA- 3.2 Filter Sizes – 20x25x4 Changed Filters – Y (provided) Blew out drain line: N Notes- performed ac tuneup. System was operational upon arrival. Found compressor over amping on startup. - this should be addressed to avoid long term damage to the compressor. No blowout valve or primary condensation shutoff. Recommended items attached. Scheduled next tune up date: 11/02 10-2