System: 3rd floor Approx. Age of System: 13 Combustible Gas Leak Detection Pipe and fittings leak-free: yes Valves and orifices leak-free: yes Carbon Monoxide Testing Walk-around CO: pass/ppm 0 Airside CO: pass /return ppm 0 supply ppm 0 Flue gas CO: pass /ppm 17 Ignition and Combustion Delayed ignition: no Flame disturbance: no Flame discoloration: no Motor Amperages and Capacitors Blower motor FLA: 3.4 Induced draft/combustion blower motor FLA: .6 Capacitor(s): NA Temperature Rise Rated: 40-70 Actual: 63 Static Pressures Blower speed/cfm: RP .06 /FR .14 /FS .52 /SP .32 TESP: Safety Controls Primary limit test: pass Filter sizes: 20x25x4 Changed filters: no Scheduled next tune up date: Notes: System was operational upon arrival. Filters are dirty and need to be replaced. Ordered a case of filters - to be delivered and filters replaced. ________________________________________ System: lower levels Approx. Age of System: 13 Combustible Gas Leak D