30045 FM 2978 Rd.
Magnolia, TX 77354
(281) 651-5484

Job Locations
for willis, tx


Map of Willis TX
Ronald  E.

Ronald E.


Job Checkin

System: left side unit Approx Age of System: 4 Combustible Gas Leak Detection Pipe and fittings leak-free: yes Valves and orifices leak-free: yes Carbon Monoxide Testing Walk-around CO: pass/ 0 ppm Airside CO: pass /return 0 ppm supply 0 ppm Flue gas CO: pass/ 86 ppm Ignition and Combustion Delayed ignition: no Flame disturbance: no Flame discoloration: no Motor Amperages and Capacitors Blower motor FLA: 4.15 Induced draft/combustion blower motor FLA: .71 Capacitor(s): pass / 4.9mfd Temperature Rise Rated: 30-60 Actual: 48 Static Pressures Blower speed/cfm: FR .32 /FS .39 /SP .17 TESP: .71 Safety Controls Primary limit test: pass Filter sizes: 20x25x1 12x12x1 Changed filters: customer replaced Notes: ________________________________________ System: right side unit Approx Age of System: 4 Combustible Gas Leak Detection Pipe and fittings leak-free: yes Valves and orifices leak-free: yes Carbon Monoxide Testing Walk-around CO: pass / 0 ppm Airside