I always request Brad to be my technician, courteous, trustworthy, honest. Good job Brad.
A/C tune up. Cleared drains and added algae tabs, washed condenser. checked entire system for safety and a/c is properly cooling the entire home and ready for hot weather
Heat maintenance, Cleared drains and added algae tabs, checked flame sensor and ignitor. completed a full safety check including checking CO2 leaks. Furnace is working properly.
annual a/c maintenance. Cleared drains and changed filter for best air flow. A/c is working safely and ready for hot weather.
annual a/c maintenance. Cleared drains and changed filter for best air flow. A/c is working safely and ready for hot weather.
Performed regular heatpump maintenance on a five year old Rudd system. I found the compressor starting hard at 87 amps. To correct I installed a new properly sized compressor saver kit to assist the compressor start up. New starting amp are undetectable.
Replaced liquid line filter/drier (leaking refrigerant) and recharged system to manufacturers specs. This 5 year old Carrier system is working to standards.
No cool found leak with leak detector on evaporator coil.
Replaced blower and board on air handler
One cool maintance checked charge and filter ok . All components April air filter ok . Cleaned and washed added alga tabs .
Checked electric heat . Found all components and safety switches OK. Filter was dirty changed out with new filter supplied by customer .
Heat maintenance checked electric heat strips and all components OK . Filter ok they supply.
Performed diagnostics on 11 year old Amana air handler
1 no cool found ants in contractor . Cleaned ants out and cleaned points on contractor . Checked pressures and put out ant poison.