I performed Scheduled Maintenance Tune-Up & Safety Check on Carrier 16 SEER 5 Ton Air Conditioner. I completed maintenance checklist. I found valve stems were missing caps. I found extra caps in service van and used them to replace missing ones. Unit was running/cooling at departure.
I performed Installation Inspection on Carrier 80& 70,000 BTU Gas Furnace & Carrier 13 SEER 2.5 Ton Air Conditioner. I found Installation to be complete and Systems to be operating as intended at time of my departure.
I completed diagnostics and found a leaking evaporator coil. I spoke with customer about repairs. The customer choosing to replace system based on age and repair cost.
I completed diagnostics and found the system is low on charge. I can’t access attic due to not having a tall enough ladder. I am returning Monday to finalize diagnosis.
Upon arrival I gave the customer an Estimate for AC unit.
I completed Estimate for Installation of New Carrier 16 SEER 3 TON Air Conditioner and removal of previous Equipment. I got the Customer Scheduled for the New Installation per his approval.
I completed the scheduled maintenance agreement cooling tune up on a Carrier air conditioner. I visually inspected the unit. Checked voltages, amps and pressures. I inspected the evaporator coil. I checked the temperature difference across the coil. Inspected heat pump. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored system. All operating normally at this time.
I performed a tune up and safety check on a Comfortmaker air conditioner. I found no issues and the system was fully operational upon departure.
During a tune up on a Rheem air conditioner, I found that everything is reading within manufacturers specifications.
I performed a tune up and safety check on a Comfortmaker Heat Pump. Everything was fully operational according to manufacturer's specifications upon my departure.
I found the Bryant heat pump not getting proper voltage. I found and removed jumper wire that is still connected to board. I also found a loose connection and tightened wires. Heat pump is operating properly at this time.
I found the Bryant heat pump not getting proper voltage. I found removed jumper wire that is still connected to board. I also found a loose connection and tightened wires. Heat pump is operating properly at this time.
Upon arrival, Comfortmaker furnace is not heating. Unit showing code 3 for pressure switch not closing. I inspected pressure switch and vacuum line and found hole in vacuum line. I repaired the hole and furnace is now running normal and heating.
I found that the filter was being pulled in some, showing air restriction. I removed the filter and system ran properly. System needs a new air filter, I explained to customer that the hyper allergenic filter is too restrictive.
I found that the filter was being pulled in some, showing air restriction. I removed the filter and system ran properly. System needs a new air filter, I explained to customer that the hyper allergenic filter is too restrictive.