Cory C.

Cory C. Job Checkin

Client requested an estimate to replace a gas furnace and air conditioner. I recommend replacing it with a Carrier 96% 80,000 BTU Gas Furnace and a Carrier 16 SEER 3 Ton Air Conditioner. Included in the estimate is a 1 year free service maintenance agreement.

Client requested an estimate to replace a gas furnace and air conditioner.  I recommend replacing it with a Carrier 96% 80,000 BTU Gas Furnace and a Carrier 16 SEER 3 Ton Air Conditioner.  Included in the estimate is a 1 year free service maintenance agreement.

Tony C.

Tony C. Job Checkin

I arrived to perform a diagnostic on an air conditioning unit. Upon arrival customer informed tech that there was a noise coming from their condenser when it turned on and off. While unit was running tech pulled disconnect and fan made a clunking sound. Tech checked wiring inside unit and capacitor. All were fine. Tech checked blade of fan. Nothing was obstructing fan. After talking to supervisor. Tech feels that fan motor is going bad. This issue has been reported by other techs who worked on unit. Customer may call back into the office to get a part replacement scheduled.

I arrived to perform a diagnostic on an air conditioning unit. Upon arrival customer informed tech that there was a noise coming from their condenser when it turned on and off.

While unit was running tech pulled disconnect and fan made a clunking sound. Tech checked wiring inside unit and capacitor. All were fine. Tech checked blade of fan. Nothing was obstructing fan. After talking to supervisor. Tech feels that fan motor is going bad.

This issue has been reported by other techs who worked on unit. Customer may call back into the office to get a part replacement scheduled.

Tony C.

Tony C. Job Checkin

I completed annual Maintenance Tune-Up & Safety Check on Bryant Air Conditioning Unit. I rinsed Coils before starting tune-up. I found and replaced dirty furnace filter with one customer provided. I performed checklist. I was getting high compressor amp readings during tune-up. Compressor looks to be going bad. Due to age of unit customer wants to get an estimate on replacement of system instead of doing any repairs.

I completed annual Maintenance Tune-Up & Safety Check on Bryant Air Conditioning Unit. I rinsed Coils before starting tune-up. I found and replaced dirty furnace filter with one customer provided. I performed checklist. I  was getting high compressor amp readings during tune-up. Compressor looks to be going bad. Due to age of unit customer wants to get an estimate on replacement of system instead of doing any repairs.

Cory C.

Cory C. Job Checkin

I performed diagnostic on Carrier Air Conditioning Unit. Customer changed their thermostat and system is no longer working. I determined that low voltage fuse had blown at circuit board. I replaced fuse and system came on properly. At some point during installation of the thermostat there was a low voltage short and tripped fuse. System is working properly now. Cooling/running at time of my departure.

I performed diagnostic on Carrier Air Conditioning Unit. Customer  changed their thermostat and system is no longer working. I determined that low voltage fuse had blown at circuit board. I replaced fuse and system came on properly. At some point during installation of the thermostat there was a low voltage short and tripped fuse. System is working properly now. Cooling/running at time of my departure.

Cory C.

Cory C. Job Checkin

I performed diagnostic on Rheem Air Conditioning Unit. I found that we were just out in July and added Freon to the system. System has leaked out all of the refrigerant that was put in to it. Customer is all set to replace Unit tomorrow. System not cooling upon departure.

I performed diagnostic on Rheem Air Conditioning Unit. I found that we were just out in July and added Freon to the system. System has leaked out all of the refrigerant that was put in to it. Customer is all set to replace Unit tomorrow. System not cooling upon departure.

Cory C.

Cory C. Job Checkin

I performed diagnostic service call on Bryant Air Conditioning Unit. I determined that motor had seized up causing fan to not be able to spin. I provided customer with quote for repair and replacement options.

I performed diagnostic service call on Bryant Air Conditioning Unit. I determined that motor had seized up causing fan to not be able to spin. I provided customer with quote for repair and replacement options.

Cory C.

Cory C. Job Checkin

I performed call back service on Carrier 13 SEER 3 Ton Air Conditioning Unit. System has a delay timer that was keeping it off. The delay was added to help with short cycling. System working properly at this time.

I performed call back service on Carrier 13 SEER 3 Ton Air Conditioning Unit. System has a delay timer that was keeping it off. The delay was added to help with short cycling. System working properly at this time.

Tony C.

Tony C. Job Checkin

I performed scheduled maintenance tune-up & Safety Check on Bryant Air Conditioning Unit. I found the compressor side of capacitor is reading in range but on the low side. I rinsed coils before doing tune-up. I found the unit to be undercharged with refrigerant. I informed customer of repair and replacement options. Customer plans to move in the near future so they have declined to make any changes at this time.

I performed scheduled maintenance tune-up & Safety Check on Bryant Air Conditioning Unit. I found the compressor side of capacitor is reading in range but on the low side. I rinsed coils before doing tune-up. I found the unit to be undercharged with refrigerant. I informed customer of repair and replacement options. Customer plans to move in the near future so they have declined to make any changes at this time.

Cory C.

Cory C. Job Checkin

I completed a diagnostic on a Trane AC unit. I found the capacitor was failing and I replaced it. I ran the system and it is now working properly.

I completed a diagnostic on a Trane AC unit. I found the capacitor was failing and I replaced it. I ran the system and it is now working properly.

Cory C.

Cory C. Job Checkin

I performed Installation of Carrier Multi-Speed X-13 2.5 Ton Electric Furnace, Carrier 14 SEER 2.5 Ton Heat Pump, Heat Kit, Honeywell T10 Pro thermostat and removal of previous Janitrol Electric Furnace/ Heat Pump.

I performed Installation of Carrier Multi-Speed X-13 2.5 Ton Electric Furnace, 	
Carrier 14 SEER 2.5 Ton Heat Pump, Heat Kit, Honeywell T10 Pro thermostat and removal of previous Janitrol Electric Furnace/ Heat Pump.

Tony C.

Tony C. Job Checkin

I performed Scheduled Maintenance Tune-Up & Safety Check on Carrier 16 SEER 2.5 Ton Air Conditioner. I completed checklist. I found a screw missing from top of cage on outside unit. May be causing rattling noise customer is hearing. I cleaned coils. Unit was running at departure.

I performed Scheduled Maintenance Tune-Up & Safety Check on Carrier 16 SEER 2.5 Ton Air Conditioner. I completed checklist. I found a screw missing from top of cage on outside unit. May be causing rattling noise customer is hearing. I cleaned coils. Unit was running at departure.

Cory C.

Cory C. Job Checkin

I performed job continuation on Carrier 13 SEER 3 Ton Air Conditioner. I replaced 15 amp fuses with proper pair of 30 AMP Buss Fuses. AC is now working properly.

I performed job continuation on  Carrier 13 SEER 3 Ton Air Conditioner. I replaced 15 amp fuses with proper pair of 30 AMP Buss Fuses. AC is now working properly.

Cory C.

Cory C. Job Checkin

I performed diagnostic service call on Bryant Air Conditioning Unit. I determined cause of water in basement was due to clogged drain line. I Pulled drain line apart and cleared with nitrogen. I Flushed drain line with bleach and hot water. I replaced 4" pleated filter at customers request. Unit is operating normally upon departure.

I performed diagnostic service call on Bryant Air Conditioning Unit. I determined cause of water in basement was due to clogged drain line. I  Pulled drain line apart and cleared with nitrogen. I Flushed drain line with bleach and hot water. I replaced 4" pleated filter at customers request. Unit is operating normally upon departure.

Cory C.

Cory C. Job Checkin

I performed diagnostic on Bryant Air Conditioning Unit. I determined that a capacitor had blown. I replaced capacitor with customers approval. I found signs of restriction and oil in the evaporator coil. The customer has chosen to replace Unit tomorrow morning due to age, condition and the costs of repairs.

I performed diagnostic on Bryant Air Conditioning Unit. I determined that a capacitor had blown. I replaced capacitor with customers approval. I found signs of restriction and oil in the evaporator coil. The customer has chosen to replace Unit tomorrow morning due to age, condition and the costs of repairs.

Tony C.

Tony C. Job Checkin

I performed diagnostic on Carrier 16 SEER 3 Ton Air Conditioning Unit. I determined that burning that customer smelled was a failed capacitor. With customers approval I replaced the In warranty Compressor-Motor Surge Capacitor. I cycled and monitored Unit. The Unit Fired up and was running/ cooling at time of my departure.

I performed diagnostic on Carrier 16 SEER 3 Ton Air Conditioning Unit. I determined that burning that customer smelled was a failed capacitor. With customers approval I replaced the In warranty Compressor-Motor Surge Capacitor. I cycled and monitored Unit. The Unit Fired up and was running/ cooling at time of my departure.