Fast and Efficient

Technician came out and identified the problem. He made service recommendations that helped us save money and set us up for continued scheduled service checks. Much appreciated.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for grove city, oh

Shane W.

Shane W. Job Checkin

RIWP (Replace In Warranty Part) - replace HP under CFAD warranty - bring old unit back & get CFAD paperwork


Cory C.

Cory C. Job Checkin

Arrived to replace outdoor PCB board on ductless mini split. Indoor head in the 3 season room has been faulting out on a code E1 sporadically for the past year but now won’t even run. Recently replaced the indoor PCB board and it didn’t fix the issue. According to Carriers service manual the outdoor PCB was the next step. Called Carrier tech support and explained issue. Found out the issue is with the wire between the indoor and outdoor unit. According to Carrier it’s supposed to be stranded wire instead of solid wire. Both heads have solid wire ran to them from the outdoor unit. Carrier has found that after a year or so of use with solid wire the indoor heads will start faulting a code E1 randomly. Install manager is informed about job and will be reaching out to the customer with a game plan and cost for replacing the wire to both indoor heads.

Arrived to replace outdoor PCB board on ductless mini split. Indoor head in the 3 season room has been faulting out on a code E1 sporadically for the past year but now won’t even run. Recently replaced the indoor PCB board and it didn’t fix the issue. According to Carriers service manual the outdoor PCB was the next step. Called Carrier tech support and explained issue. Found out the issue is with the wire between the indoor and outdoor unit. According to Carrier it’s supposed to be stranded wire instead of solid wire. Both heads have solid wire ran to them from the outdoor unit. Carrier has found that after a year or so of use with solid wire the indoor heads will start faulting a code E1 randomly. Install manager is informed about job and will be reaching out to the customer with a game plan and cost for replacing the wire to both indoor heads.

Cory C.

Cory C. Job Checkin

I replaced In Warranty OEM Main Control Board and Sensor.

I replaced In Warranty OEM Main Control Board and Sensor.

Shane W.

Shane W. Job Checkin

I went to customers home to install new filter rack and set gas pressures on a new Installation of Carrier 16 SEER 3 Ton Air Conditioning Unit and Carrier "Infinity Series" 80% 2 Stage Variable Speed 70,000 BTU Furnace.

I went to customers home to install new filter rack and set gas pressures on a new Installation of Carrier 16 SEER 3 Ton Air Conditioning Unit and Carrier "Infinity Series" 80% 2 Stage Variable Speed 70,000 BTU Furnace.

Cory C.

Cory C. Job Checkin

I performed diagnostic service call on Carrier Mini-Split Heat Pump. I determined that indoor PCB not communicating with outdoor unit. I ordered parts, Customer will be scheduled for repairs once parts arrive.

I performed diagnostic service call on Carrier Mini-Split Heat Pump. I determined that indoor PCB not communicating with outdoor unit. I ordered parts, Customer will be scheduled for repairs once parts arrive.

Cory C.

Cory C. Job Checkin

I performed diagnostic on Bryant Air Conditioning Unit. I determined that capacitor has failed. I replaced capacitor to finish diagnostic. I found the system very low on charge. After talking to customer about needed repairs, customer decided to just replace system.

I performed diagnostic on Bryant Air Conditioning Unit. I determined that capacitor has failed. I replaced capacitor to finish diagnostic. I found the system very low on charge. After talking to customer about needed repairs, customer decided to just replace system.

Tony C.

Tony C. Job Checkin

I completed spring tune up on a Trane heat pump. I visually inspected the furnace. I inspected the evaporator coil. I checked the temperature difference across the coil. Checked voltage and amps. Inspected heat pump. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored the system. Operating normally at this time.

I completed spring tune up on a Trane heat pump.  I visually inspected the furnace.  I inspected the evaporator coil.  I checked the temperature difference across the coil.  Checked voltage and amps.   Inspected heat pump.  Checked refrigerant charge, voltages and amps.  I rinsed the condenser coils with water.  Cycled and monitored the system.  Operating normally at this time.

Cory C.

Cory C. Job Checkin

I completed a diagnostic on a Bryant AC unit. I found the unit was low on charge and I talked with the customer about repairs. The customer decided they would like an estimate for a replacement and would let us know.

I completed a diagnostic on a Bryant AC unit. I found the unit was low on charge and I talked with the customer about repairs. The customer decided they would like an estimate for a replacement and would let us know.

Cory C.

Cory C. Job Checkin

I gave an estimate to install a Carrier 16 SEER 3.5 Ton Air Conditioner and a Carrier "Infinity Series" 80% 2 Stage Variable Speed 90,000 BTU Gas Furnace. I included in the estimate is a 1 year free service maintenance agreement and removal of current Lennox HVAC System.

I gave an estimate to install a Carrier 16 SEER 3.5 Ton Air Conditioner and a Carrier "Infinity Series" 80% 2 Stage Variable Speed 90,000 BTU Gas Furnace. I included in the estimate is a 1 year free service maintenance agreement and removal of current Lennox HVAC System.

Cory C.

Cory C. Job Checkin

I completed a diagnostic on a Bryant AC unit. I found the capacitor dead and not turning on the compressor or fan. I replaced the capacitor and ran the system. The system is now operational.

I completed a diagnostic on a Bryant AC unit. I found the capacitor dead and not turning on the compressor or fan. I replaced the capacitor and ran the system. The system is now operational.

Tony C.

Tony C. Job Checkin

I completed the scheduled maintenance agreement cooling tune up on a Carrier air conditioner. I visually inspected the unit. Checked voltages, amps and pressures. I inspected the evaporator coil. I checked the temperature difference across the coil. Inspected heat pump. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored system. All operating normally at this time.

I completed the scheduled maintenance agreement cooling tune up on a Carrier air conditioner.  I visually inspected the unit.  Checked voltages, amps and pressures. I inspected the evaporator coil.  I checked the temperature difference across the coil.  Inspected heat pump.  Checked refrigerant charge, voltages and amps.  I rinsed the condenser coils with water.  Cycled and monitored system.  All operating normally at this time.

Tony C.

Tony C. Job Checkin

Scheduled maintenance cooling tune up on a Carrier 16 SEER 2.5 Ton Air Conditioner air conditioner completed. I visually inspected the furnace. Checked voltage and amps. I inspected the evaporator coil. I checked the temperature difference across the coil. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored the system. Operating normally at this time.

Scheduled maintenance cooling tune up on a Carrier 16 SEER 2.5 Ton Air Conditioner air conditioner completed.  I visually inspected the furnace.  Checked voltage and amps. I inspected the evaporator coil.  I checked the temperature difference across the coil.   Checked refrigerant charge, voltages and amps.  I rinsed the condenser coils with water.  Cycled and monitored the system.  Operating normally at this time.

Cory C.

Cory C. Job Checkin

I completed scheduled maintenance tune-up and safety check on Comfortmaker Air Conditioning Unit. I found delta was high during checkout. I verified filter and blower motor/wheel were clean. I determined blower speed needed adjusted. I got second opinion with supervisor. I adjusted dip switches to get proper airflow. System now operating within specs.

I completed scheduled maintenance tune-up and safety check on Comfortmaker Air Conditioning Unit. I found delta was high during checkout. I verified filter and blower motor/wheel were clean. I determined blower speed needed adjusted. I got second opinion with supervisor. I adjusted dip switches to get proper airflow. System now operating within specs.

Tony C.

Tony C. Job Checkin

I performed scheduled maintenance tune-up & safety check on Five Star 13 SEER 3 Ton Air Conditioner. I completed tune-up checklist. I found there is no filter in cabinet. I found new filter of wrong size and used it for the time being. Customer has now ordered correct size filter and will install on arrival. Unit met specifications at departure.

I performed scheduled maintenance tune-up & safety check on Five Star 13 SEER 3 Ton Air Conditioner. I completed tune-up checklist. I found there is no filter in cabinet. I found new filter of wrong size and used it for the time being. Customer has now ordered correct size filter and will install on arrival. Unit met specifications at departure.

Shane W.

Shane W. Job Checkin

I performed a job continuation on Carrier gas furnace. I had to de-install in order to replace 60x30 drain pan that is blocking door with a 30x30 drain pan. System is now operating as intended upon departure.

I performed a job continuation on Carrier gas furnace. I had to de-install in order to replace 60x30 drain pan that is blocking door with a 30x30 drain pan. System is now operating as intended upon departure.