He was courteous, efficient and maintained all the safe standards.
I appreciate the fast service when my furnace was out during the extremely cold I appreciate your fast service getting my furnace back in working condition during the extremely cold weather.
Great service. Chris was very professional and explained everything to me. He made sure I understood how to work the new thermostat before he left.
Chris and Luke were at my home to inspect the furnace and do the winter check-up. They were courteous, professional, and preformed the work skillfully. Thank your for your prompt and efficient service. Happy Holidays.
I returned to a home that had recently had work done, but was experiencing the same issue that it had when I had performed work in the home last. Upon my arrival to the home, customer stated ac wasn't working anymore blowing the fuse again. Found bad contactor blowing the fuse. Replaced. Ac comes on properly and no longer blows fuse.
I returned to a home that had recently had work done, but was experiencing the same issue that it had when I had performed work in the home last. Upon my arrival to the home, customer stated ac wasn't working anymore blowing the fuse again. Found bad contactor blowing the fuse. Replaced. Ac comes on properly and no longer blows fuse.
Scheduled maintenance cooling tune up on a Carrier 13 SEER 2.5 Ton Air Conditioner completed. I visually inspected the furnace. Checked voltage and amps. I inspected the evaporator coil. I checked the temperature difference across the coil. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored the system. Operating normally at this time.
I completed a diagnostic on a Carrier air conditioning unit. I determined that the unit was low on Freon and I added R-410A refrigerant. Operational at time of departure.
I completed SMA Spring Tune-Up and Safety Check and found everything to be within manufacture specifications. The unit is operational upon departure.
I completed SMA Spring Tune-Up and Safety Check and found everything to be within manufacture specifications. The unit is operational upon departure.
Upon arrival I replaced the OEM blower and capacitor. The system is operational upon departure.
I completed diagnostic call on Bryant Air Conditioner. I determined that compressor is failing. System is operating as intended at time of departure. I notified customer that the compressor would need replaced the next time this issue occurred.
Scheduled maintenance cooling tune up on a Bryant air conditioner completed. I visually inspected the furnace. Checked voltage and amps. I inspected the evaporator coil. I checked the temperature difference across the coil. Checked refrigerant charge, voltages and amps. I rinsed the condenser coils with water. Cycled and monitored the system. Operating normally at this time.
I performed a tune up and safety check on a Bryant air conditioner. I found no issues and the system was fully operational when I left.
During a tune up on a Carrier 13 SEER 2 Ton Air Conditioner, I found that everything is operating within manufacturers specifications. All good at this time.
During a tune up on a 2012 Bryant gas, I found that the blower capacitor is failing so I replaced for customer. The furnace also has a lot of rust on the inside bottom from a previous leak. Furnace is operating at time of departure.
I performed a tune up on a Trane gas furnace
I am Performing our Five Star Tune-Up & Safety Check on a 2005 Trane Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.