Shane W.

Shane W. Job Checkin

I completed an installation inspection on a Carrier 13 SEER 2.5 Ton Air Conditioner. Completed installation checklist. Repositioned flue. Removed tape from coil to furnace and sealed edges with silicone because tape was already peeling off. Replaced section of metal 4” flue. Cycled and monitored the system. Operating normally at this time.

I completed an installation inspection on a Carrier 13 SEER 2.5 Ton Air Conditioner.  Completed installation checklist. Repositioned flue. Removed tape from coil to furnace and sealed edges with silicone because tape was already peeling off.

Replaced section of metal 4” flue. Cycled and monitored the system.  Operating normally at this time.

Cory C.

Cory C. Job Checkin

I arrived to perform a diagnostic on an air conditioner. Upon arrival, customer stated system wasn’t cooling home. Found system low on charge. Based on cost of repairs, customer is replacing ac.

I arrived to perform a diagnostic on an air conditioner. Upon arrival, customer stated system wasn’t cooling home.

Found system low on charge. Based on cost of repairs, customer is replacing ac.

Cory C.

Cory C. Job Checkin

I arrived to perform a diagnostic on an air conditioner. Upon arrival, customer stated system wasn’t cooling home. Found system low on charge. Based on cost of repairs, customer is replacing ac.

I arrived to perform a diagnostic on an air conditioner. Upon arrival, customer stated system wasn’t cooling home.

Found system low on charge. Based on cost of repairs, customer is replacing ac.

Shane W.

Shane W. Job Checkin

MISCELLANEOUS: Materials needed 1 section 12x24 Duct 2 caps 10" A collars qty 2 5ft 10 inch pipe qty 1 10" Elbows qty 3


Cory C.

Cory C. Job Checkin

I performed diagnostic service call on rental property air conditioning unit. I found that R wire shorted to ground somewhere from outdoor to indoor. I changed R wire to brown. System now comes on properly with no issues. Cooling/running upon departure.


Shane W.

Shane W. Job Checkin

I completed job continuation on a newer Install. I replaced Aprilaire Media Cabinet with FilxCab 24".

I completed job continuation on a newer Install. I replaced Aprilaire Media Cabinet with FilxCab 24".

Shane W.

Shane W. Job Checkin

I performed a job continuation on Carrier 16 SEER 5 Ton Air Conditioning Unit. I replaced aprilaire media cabinet with FilxCab 24" & change out humidifier to 700M. System is operating as intended upon departure.

I performed a job continuation on Carrier 16 SEER 5 Ton Air Conditioning Unit. I replaced aprilaire media cabinet with FilxCab 24" & change out humidifier to 700M. System is operating as intended upon departure.

Shane W.

Shane W. Job Checkin

I went to the customer's home to do an inspection for Carrier Air Conditioning unit installation.

I went to the customer's home to do an inspection for Carrier Air Conditioning unit installation.

Cory C.

Cory C. Job Checkin

I performed yearly maintenance tune-up & safety check on Lennox Air Conditioning Unit. I completed tune-up checklist. I rinsed coils for customer. I checked amps, voltage and pressure. System is operating as intended at this time.

I performed yearly maintenance tune-up & safety check on Lennox Air Conditioning Unit. I completed tune-up checklist. I rinsed coils for customer. I checked amps, voltage and pressure. System is operating as intended at this time.

Tony C.

Tony C. Job Checkin

I performed scheduled maintenance tune-up & Safety Check on Carrier 13 SEER 3 Ton Air Conditioning Unit. I checked pressures, amps and voltages. I completed checklist. I found system to be undercharged. I added required amount of refrigerant. I cycled and monitored unit. System is operating as intended upon departure.

I performed scheduled maintenance tune-up & Safety Check on Carrier 13 SEER 3 Ton Air Conditioning Unit. I checked pressures, amps and voltages. I completed checklist. I found system to be undercharged. I added required amount of refrigerant. I cycled and monitored unit. System is operating as intended upon departure.

Cory C.

Cory C. Job Checkin

I performed Installation of Carrier 16 SEER 3.5 Ton Air Conditioning Unit and removal of previous equipment.

I performed Installation of Carrier 16 SEER 3.5 Ton Air Conditioning Unit and removal of previous equipment.

Cory C.

Cory C. Job Checkin

I performed diagnostic on Mini Split System. I determined drain line was not properly ran causing water to not drain. I correct drain line. System is now operating as intended.

I performed diagnostic on Mini Split System. I determined drain line was not properly ran causing water to not drain. I correct drain line. System is now operating as intended.

Tony C.

Tony C. Job Checkin

I performed scheduled maintenance Tune-Up & Safety Check on Carrier up to 17 SEER 2 STAGE 4 Ton Air Conditioner. I found the condenser to be unlevel. Condenser is leaning forward. Unit met all specifications upon departure.

I performed scheduled maintenance Tune-Up & Safety Check on Carrier up to 17 SEER 2 STAGE 4 Ton Air Conditioner. I found the condenser to be unlevel. Condenser is leaning forward. Unit met all specifications upon departure.

Shane W.

Shane W. Job Checkin

1I performed Installation Inspection On Carrier 13 SEER 3 Ton Air Conditioner Unit and removal of previous Trane Air Conditioning Unit.

1I performed Installation Inspection On Carrier 13 SEER 3 Ton Air Conditioner Unit and removal of previous Trane Air Conditioning Unit.

Cory C.

Cory C. Job Checkin

I pewrformed diagnostic service call on Trane Air Conditioning Unit. I determined that system was low on charge. I added required amount of refrigerant to system. I cycled and monitored system. Running/cooling as intended at departure.