521 J PL 625
Plano , TX 75074
469-252-0599

Job Locations
for frisco, tx


Map of Frisco TX
Nathanr@chromeairconditioning.com

Nathanr@chromeairconditioning.com


Job Checkin

Completed a two system Fall Maintenance. Found several issues with main system of home. *Main* -Several burn marks and burnt resistors on primary circuit board -Flame sensor needs to be replaced due to heavy carbon build up. -Ignitor has how white spots and needs to be replaced. -High limit is not safely shutting furnace off and is allowing furnace to exceed 500°s. -Pressure switch isn’t faulty and not safely shutting gas off of inducer draft motor was to fail. -Drain pan heavily rusted and needs to be replaced. -Ducting is dirty and needs to be cleaned. **Possible heat exchanger failure/Unable to detect currently due to not having inspection camera.**/Heat exchanger is making loud expanding/popping noises under normal heating operation. *Secondary System* -Burns marks on back of primary circuit board -Flame sensor needs to be replaced due to carbon buildup. -Ignitor is beginning to get hot white spots -Drain pan heavily rusted. *Not allowed to enter home and cust