Performed a plumbing inspection checking all faucets, drains, cut off valves, checked water heater, T&P valve, opened up drain valve for water heater and noticed the water was black, checked toilets and hose bibs. Found that the stops in the second bathroom need to be replaced, hot side on both are not closing. P-trap is clogged up on right sink which has the a/c draining into it. Found that the stop in master bathroom sink closest to closet need to be replaced stop doesn’t close. Found that the kitchen sink stops need to be replace, dishwasher stop is leaking when closing, and sink stop hot side. Found that the water heater needs to be flushed and T&P valve doesn’t close all the way when opened. Sent estimate over to make repairs.