Job Checkin

Upon arrival found that the system wasn’t cooling. Checked inside unit and found everything operational, checked outdoor unit and found the compressor not running but fan motor running. Checked capacitor and found it dead, replaced capacitor and compressor came on. Checked pressures and amp draws both looked good system is now cooling at this time.