521 J PL 625
Plano , TX 75074
469-252-0599

Job Locations
for prosper, tx


Map of Prosper TX
Angela E.

Angela E.


Job Checkin

Upon arrival found system short cycling. Checked inside unit and found coil frozen up. Checked filter and found it dirty. Homeowner stated that they just changed out the filter Friday. Turned down run time for fresh air intake. Left Tstats on and shut off outdoor condenser. Will need to return once coil is thawed out to see if it’s a refrigerant issue or air flow. Upon arrival had no answer at the door. Rang doorbell and knocked on the door, got no answer. Upon arrival turned system on and checked pressures. Pressures looked good. Filter was the cause of system icing up. Recommended adding start assist to compressor to ease the start up since it is a zoned system and turns on more than a normal set up.