1570 Old York Road
Abington, PA 19001
215-659-4343

Job Locations
for warminster, pa


Map of Warminster PA
Paul T.

Paul T.


Job Checkin

Performed preventative maintenance for a Lennox furnace model #SL280UH090V36B-03, serial #5915E14212. I powered the system down and removed the access panels. I removed and cleaned carbon off of the flame sensor and cleaned out the burners and burner box. The homeowner supplied her own pure air kit however the homeowner bought the wrong size. The homeowner had some spare uv bulbs that I replaced and I installed a 16x25x1 air filter until the homeowner can get the correct Merv air filter. I checked the pressure switch for clogs and tested the drain line and condensate pump with several bottles of water to ensure that there are no leaks or clogs. I checked all electrical connections to ensure that they are secure and in good condition. I powered the system back up and called for heat. I took a combustion analysis test and received the following readings, o2 is at 12.2% and the co levels are 5ppm. The inducer motor amp draw is at .21 and the blower motor amp draw is at 4.6. The system is