I appreciate your advice regarding keeping the fan off during the summer months to keep the house from feeling damp. Even in one day I can already tell the difference, despite the heavy rains these last two days. Thank you!
Sean was amazing!! Super great guy very knowledgeable and professional. I love Classic Aire!! They do business the old fashion way with all the advantages of modern technology. I feel very safe with my furnace cleaned & checked by Classic
Quick, clean and thorough. Dave is great as always.
I needed to see a doctor suddenly. The dispatcher and technician moved me to the end of the queue to accommodate that. Very good service on AC unit and good price on the filter I needed.
Dave always does a good job. I trust him. Today that's hard to say about people or a company.
I have been doing business with this company for 25 years, since it was Schneider. My overall experience has been excellent. The most recent experience was the purchase and installation of a new A/C system. I feel the price I paid for the quality I received was outstanding. The installers did a great job in a half day installation. They were professional, efficient and courteous. As I said, great experience!!
Shawn did an outstanding job. He explained what he was doing as he worked which helped me to better understand the system.
I think Dave did an excellent job. He is friendly, quick and seems to do his work well.
Stan is an excellent representative of your company. He was prompt, courteous and quickly solved the problem.
Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced thermostat batteries. Replaced 1” filter with 4” media. Replaced UV lamp for APCO air purifier and swapped leads. Customer replaced humidifier pad. Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced thermostat batteries. Replaced 1” filter with 4” media. Replaced UV lamp for APCO air purifier and swapped leads. Customer replaced humidifier pad.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. test humidifier. Customer changes water panels. Customer complaint of noise. I adjusted heating and cooling blower speeds to reduce noise. Blower: 1.5/2.1A . Inducer: 0.09/0.21A . Gas pressure: 2.0/3.2 inches water column. Temperature rise: 51/57 . Supply: 120/126 . Return: 69 .
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Blower: 4.0A . Inducer: 0.69A . Gas pressure: 3.4inches water column. Temperature rise: 48 . Supply: 79 . Return: 127 . Humidifier not working. I found humidifier supply valve clogged. I replaced with ball valve. Clean humidifier, replace pad, checked water flow and drain. Paid by Visa.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Clean and check humidifier, replace pad, checked water flow and drain. Blower: 3.7A . Inducer: 1.3A. Gas pressure: 3.4 inches water column.
Customer complaint: air-conditioner not keeping up with set temperature of 73. Checked AC operation. Compressor: 9.2A . Condenser fan: 0.82A . Blower: 5.8A, 1100cfm . ambient: 91 . liquid line: 96 . suction line: 56 . metering device: TXV . Suction pressure:124(43) . Return air: 72.5 . supply air: 52.0. wet bulb: 60 . Unit is cooling properly. Checked filter: True Blue. Room addition has attic air entering from leaky canned lights! Room addition has portable air conditioner. I found warm humid air infiltrating into basement from under room addition slab. Basement pressure is slightly negative (- .005 inches water column) with basement door closed, causing additional air infiltration into basement and downdraft of flu vent. Work suggested: recommend 3M brand air filters. Seal air leaks into attic at recessed lighting in room addition. Have insulation in attic checked. Remove basement door or Block basement door from closing all the way to keep pressures
Found system low on Freon. Topped off Freon for temporary cooling. Expect Freon will leak back out. Customer declined leak search at this time. System uses old type of Freon (R22) Checked temperature drop. 15.5. Recommend adjusting blower speed lower. Customer complaint: Had to push in contactor to get AC going last year(happened twice). Work suggested: Freon leak search: $189. Freon leak repair: $? Recommend second transformer for UV lamp.
Serviced air conditioner and replaced filter and replaced capacitor
Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Replaced thermostat batteries. Replaced air filter. Compressor: 6.25A.Condenser fan: .85A .ambient: 50 .liquid line: 58.suction line: 51 .metering device: TXV . Return air: 71 .supply air: 50 .