Over the years my experience has been good with you and is helpful especially when winter sets in and seniors are inside for more hours than ever‼️
Jeff is very experienced and a great personality. Always on time and service completed in a timely manner.
The first technician who came out was still learning and it took him a long time to diagnose the problem. I had to wait for a part to be ordered. I was without air conditioning for two days and had to leave work twice to complete the repair which was inconvenient. In the end, we didn't need the part and if Roger had come out the first time my air conditioning would have been fixed on the first trip. Everyone needs to learn, I was lucky temps were moderate but I lost work time twice this week which was very inconvenient.
The best set of knowledgeable people I have ever had the pleasure of dealing with.
Had A/C maintenance done as part of the Planned Maintenance Agreement. The technician found that the dual capacitor was in bad shape so I had that replaced, and it was partly covered by the Carrier warranty. There's a lot to be said for preventive maintenance, especially when it is done by a reliable company. I've been a Classic Aire Care customer for 7 years now.
Jeff was great. He was a true gentleman and very respectful of my property. You could use more men like Jeff. I want him to be my go to man for all my heating and cooling needs!
Service and some needed changes over the years have been successful and appreciated. A new furnace and removal of a “built in “ humidity regulator which we inherited when we bought the house, made our air healthier — especially for my husband.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced air filters. Blower: 8.7A . Inducer: 1.04A. Gas pressure: 3.6 inches water column. Temperature rise: 54 . Supply: 125 . Return: 71 .
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Blower: 7.5A . Inducer: 1.4A Gas pressure: 3.5 inches water column. Temperature rise: 60 . Supply: 126 . Return: 66.
Cleaned & checked 2 condensing gas furnaces. Inspected heat exchangers & flue venting. cleaned burners & flame sensors. Checked voltage & amp draw of motors. Test capacitors. Checked filters. Second floor system: Blower: 5.3A. Inducer: 0.4A . Gas pressure: 3.4inches water column. Found oil on second floor furnace due to Freon leak. I pumped down air conditioner system, purged with nitrogen, and repaired leak. Evacuated system and opened service valves. We need to top off the Freon level at next maintenance visit. First floor system: Blower: 7.0A . Inducer: 0.7A . Gas pressure:3.4 inches water column. Clean and check humidifier, replace pad, checked water flow and drain.
Cleaned & checked 2 gas furnaces. Inspected heat exchangers & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Second floor: Checked temperature rise. 47. Supply: 121. Return:75. First floor: Temperature rise: 48 . Supply: 122 . Return: 74 . Clean and check 2 humidifiers, replace pad, checked water flow and drains.
Fall maintenance today for the furnace!
Complaint: it’s 55 degrees this morning. Currently about 64. found boiler operational at this time. Found rooftop unit showing E1,E2,E4. I resent rooftop unit. set up default cool temperature at main control to 70. Turned up VAV controllers. I set up boiler reset temp: raised lower limit and upper limit, Resulting in 25 degree higher current set point.
Furnace maintenance today. Found hole in flue pipe....returning to replace
Fall maintenance today for both home furnaces! Installed an Apco UV purifier!
Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked and cleaned out drain. Checked filter. cheched venting. Blower: 6.2A . Inducer: 1.76A . Gas pressure: 3.5 inches water column. Temperature rise: 69 . Supply: 149. Return: 80 .
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Humidifier: did not service. Blower: 2.2/4.0A . Inducer: 0.32/1.55A . Gas pressure: 1.8/3.5 inches water column. Temperature rise: 50/55 . Supply: 127/132 . Return: 77 .
Serviced furnace and humidifiers
Fall maintenance today for the furnace!
Fall maintenance for the furnace today!
Fall maintenance! Replaced the filter and run capacitor