he has helped us several time and is always very good at what he does.
I will request future service calls from Classic Aire.
Coret took the time to explain how the system works and how to best maintain it for optimum service.
Roger arrived in the time period agreed upon, and did a great job servicing the air conditioner.
I cannot say that I have ever felt more confident that a technician understood and represented my needs as much I do with Classic Aire Care. He let's us know in advance what may need replacement in the future allowing us time to plan. The technician is very thorough and takes the time for a complete analysis. Thanks for the confidence!
Spring service call was done expertly. Needed to add a piece to control mold and bacteria found. Roger explain the options available for my unit. Purchased one item. All done same day. Great job by Classic Aire Care.
Thanks for the information about the air filter & purifier options.
The service as always was great told me what I needed
Tech. arrived shortly after I received the call that he would be on his way. Service was quick and professional.
Thanks for the fast service and allowing me to pay by check using my self-directed IRA. Ron Nash
We have had Classic Aire servicing our home unit for several years. The honesty and quality of service they deliver is not seen often anymore. I believe the service technician, Corey, is who truly makes the difference, but the company supports him. Highly recommend Classic Aire Care, and super recommend Corey!
The gentlemen did a great job explaining what she was going to do and why. He was very thorough in his cleaning and then again went over what the results were when he was done. He seemed to truly enjoy his job working for Classic Aire Care.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Found run capacitor weak: 11%low. Replaced capacitor and tested amp draw. customer declined humidifier service. Adj Blower: H:3.4A . Inducer: 0.6A . Temperature rise: 61 . Supply: 139 . Return: 78 .
I found condenser coil extremely dirty, requiring chemical cleaning. I performed chemical cleaning of condenser coil. Back flushed coil with water saber. I rechecked Freon pressures. Indoor blower moving excess air. Recommend adjustment. Minor dents to condenser coil fins are insignificant. Causing no problem or efficiency reduction. Electronic air cleaner cells are in need of chemical cleaning. Prefilters should be installed in front of electronic air cleaner cells. Compressor: 8.3A . Condenser fan: 0.43A . ambient: 87. suction line: 55 . metering device: piston . Suction pressure: 79(47). wet bulb:66 . System is cooling OK. Work suggested: chemical cleaning of electronic air cleaner cells. Blower speed adjustment.
No ac service call—dual capacitor shorted on compressor side
Arrived checked in with customer. Checked unit operation to find compressor not running checked power, tested capacitor to find compressor cap out of range. Checked compressor to find open and hot will need to allow compressor to cool. Left unit off at disconnect. Return Sunday, May 28, 2018: Checked filter. Checked blower. replaced bad dual capacitor. Tested operation. Compressor: 9.1 A. Fan motor: .84 A. Ambient: 88. Suction: 143(50). Suction line: 75. Liquid line: 97. Blower: 3.0 A. Lennox Model XC14-036-230-03 Serial 5810H08534
Checked out system found unit low on refrigerant customer to get estimate
Serviced air conditioner and replaced filter
Serviced air conditioner and replaced filter
Inspected furnace found bad limit,and cracked heat exchangers.tagged and shut off