John called when he was on his way (as I had requested) and showed up on time and resolved the situation very quickly. Had the part with him and saved another trip. I gave a 3-star rating for the price because about five years ago I had a similar service done for less than one-third the price. Yes, I understand that everyone's costs have risen, but tripled?
it is nice(very seldom received) to speak to a person when communicating over the telephone about a service required.
we would love to have him back at the next visit he knows his job and has a wonderful smile and a great personality.
Recommend Classic Aire to everyone!
Best a/c company in St.Louis#
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Blower: 3.4A . Inducer: 1.03A . Gas pressure: 3.5 inches water column.
Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Compressor: 5.3A . Condenser fan: 0.78A . ambient: 75 . liquid line: 76 . Condenser: dirty. suction line: 45 . metering device: piston . Suction pressure: 68(40) . Return air: 73 . supply air: 54 . wet bulb: 59. SH: T-3. Back-flushed condenser coil with Water-Saber. Replaced air filter.
Found flame sensor current very low. Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Blower capacitor weak: 19% low. Customer declined repair. Replaced dirty air filter.
Control board flashing code 3: limit circuit open. Reset roll-out safety. Showed customer. Tested operation. Checked draft inducer: .79 A. Checked draft of flue: .06 inches water column. I also checked temperature at rollout safety: 152. Roll out rating: L250. Checked gas pressure. Creeping up to 3.6 inches water column. Customer declined gas pressure adjustment.
checked gas furnace. Inspected flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Inspected heat exchanger and found crack in chamber number two! I turned off switch to furnace, turn off gas to furnace and tagged as potential CO hazard.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced air filter. Blower: 4.4A . Inducer: 1.45A . Clean and check humidifier, replace pad, checked water flow and drain.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Tested thermostat batteries. Clean and check humidifier, replace pad, checked water flow and drain. Blower: 2.2A. Inducer: .08/.18A .