1276 N. Warson
St. Louis, MO 63132
(314) 352-1111

Job Locations
for st. louis, mo


Map of St. Louis MO
John M.

John M.


Job Checkin

Pumped down system. Removed closet doors. Removed and replaced evaporator coil of air handler. Pressurized to test connections for leaks. Evacuate low side. Topped off Freon level. Repaired closet door track and reinstall doors. liquid line: 86. suction line: 52 . metering device: TXV . Suction pressure: 138(40). head pressure: 282(92). Clean and check electric furnace. Tested heating elements. 58A. 209V. Tested sequencers. Checked voltage & amp draw of blower: 1560cfm. Replaced air filter. Clean and check humidifier, replace pad, checked water flow and drain. Set humidistat and dampers. Customer had to leave. Balance due for humidifier service and air filter.