Furnace checkup

On time, careful, courteous. Helps keep our boiler clean and functioning.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

I appreciate the company sending John per my request.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Awesome service

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

The service was well done by an experienced service man who has been to my house several times.

Servive was well done.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

Service was quickly set up and Jake Kelly, the service tech was knowledgeable and professional. Said Nest thermostats routinely have problems when they are not connected to a common wire which he promptly hooked up and fixed the problem. It would seem this would be a standard item the installers would look for and correct to avoid post-install service calls.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Check up

John was terrific. Explained things. Answered questions. Was efficient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Maintenance

The scheduled air conditioning pre-season Maintenance was great as usual

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

It was great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service, Friendly People

Classic Are Care always does a very thorough job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Gas Valve

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very prompt and great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

WENT RIGHT TO WORK

Roger came in and asked about the problem. Then went right to work solving my problem. He guessed the problem and explained and /or answered any of my questions about my boiler.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Donald

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for university city, mo

John M.

John M. Job Checkin

Customer complaint: temperature is not dropping down at night like she sets it. Staying 65 to 66. I traced down thermostat wiring at zone control and aquastat and found a second thermostat paralleled together. The cooling system thermostat can also control boiler heat. It was set at heat and 68.


John M.

John M. Job Checkin

Bedroom A/H: 2577: Checked temperature rise. 33. Replace drain pan level sensor. Tested HP operation. Tested sensor.


John M.

John M. Job Checkin

Cleaned and checked gas boiler. Checked voltage & amp draw of pump. Inspected heat exchanger & flue venting. cleaned burners & pilot assembly. Boiler is in poor. Combustion chamber has warped front and back panels. Some flue gases are spilling from boiler! Condition can worsen quickly. Recommend replacing boiler. Second-floor bedroom has leaking radiator valve. Recommend replacing. Boiler appears to be about 50 years old. Suggestions: Strongly recommend replacing boiler and radiator valve.


John M.

John M. Job Checkin

I found thermostat batteries very weak. I replaced thermostat batteries. Tested heat operation.


John M.

John M. Job Checkin

Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Blower: 1.6/2.4A . Inducer:0.08/0.25A . Gas pressure: 1.9/3.9inches water column. Temperature rise: Stg2: 53 . Supply: 124 . Return: 71 .


John M.

John M. Job Checkin

Cleaned & checked gas furnace in attic(second floor system)a. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Blower: 4.4A . Inducer: 0.6A. Gas pressure: 3.6 inches water column. Temperature rise: 74 . Supply: 152 . Return: 74 . Cleaned and checked gas boiler. Checked voltage & amp draw of pump. Inspected heat exchanger & flue venting. cleaned burners & pilot assembly. Secured front insulation panels. Drain water and pressurized Extrol tank to 13 psi. Boiler pressure gauge is not accurate. Bleed air from system. Turned on dining room radiator. Pressure: 13. Supply: 94. Return: 86. Cleaned & checked condensing gas furnace(rear system). Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced air filter. Clean and check humidifier, replace pad, checked water flow and drain. Blower: 3.4/4.7A. Inducer:


John M.

John M. Job Checkin

Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced air filter. Blower: 5.5A. Inducer: 1.75A . Gas pressure: 3.4 inches water column. Customer has gravity boiler that leaks flue gasses at warped upper access doors. Suggestions: boiler is a potential CO hazard. Recommend replacing boiler.


John M.

John M. Job Checkin

Cleaned and checked gas boiler. Checked voltage & amp draw of pump. Inspected heat exchanger & flue venting. cleaned burners & pilot assembly. Found expansion tank water logged. I drained expansion tank. Tested boiler operation with combustion analyzer. CO: 200+. Fine tuned for proper burn. Adjusted combustion air door. Adjusted gas pressure: 2.85 inches. Carbon monoxide: 85 ppm. Oxygen: 5.1%. Stack: 530. Rate: 219,000 BTU.


John M.

John M. Job Checkin

Gravity boiler (1920 Mueller model number: 1-28-W, serial: 44248) Burner cover was not put in place properly. Found system needed more water. Added water and bled air third-floor radiator. Other third-floor radiator has broken vent Found expansion tank waterlogged. May cause excessive pressure and water release at pressure relief valve. Combustion gases are leaking at front and rear access doors. Boiler in need of cleaning and sealing. Boiler will need tuning with combustion analyzer for proper primary, secondary, and gas pressure adjustments. Thermostat cycles too fast for gravity type system. (Efficiency loss). Has very old white Rodgers digital thermostat with no cycle rate adjustment instructions available. Customer is planning to sell the home. Wants pricing to replace boiler.


John M.

John M. Job Checkin

Cleaned and checked gas steam boiler. Inspected and cleaned heat exchanger. Checked flue piping and draft. Cleaned burners, pilot, and flame sensor. Blow down and test low-water cut off. Retest: working OK. Checked manifold gas pressure. Topped off water level.


John M.

John M. Job Checkin

Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked filter. Checked drain. Clean and check humidifier, replace pad, checked water flow and drain. Blower: 5.2A . Inducer: 1.88A . Gas pressure: 3.4 inches water column. Temperature rise: 62 . Supply: 132 . Return: 70 . Rear system: system amps: 2.1. Supply air: 96. Return: 75. Office: Supply: 124. Return: 84. Bedroom: indoor unit shut off and would not run. Retrieved fault code. Indoor air sensor fault. I bypassed drain pan level sensor wiring to correct fault code. Need to replace drain pan level sensor. Suggestions: need to add humidifier to maintenance plan. replace drain pan level sensor for indoor unit in second-floor bedroom.


John M.

John M. Job Checkin

I drain the boiler and replaced pump. Drain entire system and replaced it leaky gate valve. Also drain expansion tank. Refilled system and bled air from accessible radiators.


John M.

John M. Job Checkin

Cleaned & checked 3 gas furnaces and 1 Cleaned and checked gas boiler. Inspected heat exchanger & flue venting. cleaned burners, pilot & flame sensors. Checked voltage & amp draw of motors. Test capacitors. Replaced air filters. Boiler: supply: 107. Return: 93. Tested pressure relief. Checked vent. Main: Inducer: 1.75A. Blower: 6.8A. Checked temperature rise. 66. East: blower: 2.0A. Inducer: 0.9A. Checked temperature rise. 52. Rear: Inducer: 1.33A. Blower: 3.5A. Return: 69. Checked heat tape. Checked drain.


John M.

John M. Job Checkin

Cleaned and checked gas boiler. Cleaned burners & pilot assembly. Checked voltage & amp draw of pump. I found expansion tank waterlogged! I installed valve and drained tank. Drained expansion tank. I found thermostat “system” switch has bad connection. Replaced thermostat. Bled air from system.


John M.

John M. Job Checkin

Cleaned and checked gas boiler. inspected, cleaned heat exchanger. Checked flue venting. Cleaned burners & pilot assembly. Checked pressure Checked voltage & amp draw of pump and found pump motor locked up! Needs new pump. Found gas order at boiler. Located leak source: corroded pilot tubing! Picked up new and replaced pilot tubing and fittings. Reinstalled pilot into boiler. Also found gate valve on supply side leaking. Work suggested: replace circulator pump and Leaky isolation valve: see estimate. Wants repair done Tuesday if possible.